Performance Analysis of Hydrocarbon Mixture to Replace R134a in an Automotive Air Conditioning System

Article Preview

Abstract:

At present, most air conditioners in an automotive use R134a as working fluid. Due to the negative impact on the environment, i.e. global warming, the refrigerant must be replaced by environmental friendly working fluid. Hydrocarbons are natural fluids, no effect on the climate, inexpensive and readily available. The hydrocarbon mixture used in the present study is R436A, composed of R290 (propane) and R600a (isobutane) with a mass ratio of 56/44. The results show that the drop-in substitute from R134a to R436A reduced COP by 4.84, 4.74 and 4.64% for the condenser temperature of 40, 45 and 50°C, respectively. To generate COP improvement on the drop-in substitute, subcooling was carried out, and results show that the COP improvement was 4.42, 5.20 and 6.09% for the condenser temperature of 40, 45 and 50°C, respectively.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

444-448

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] S. Wongwises, A. Kamboon and B. Orachon, Experimental investigation of hydrocarbon mixtures to replace HFC-134a in an automotive air conditioning system, Energy Convers. Manage. 47 (2006) 1644-1659.

DOI: 10.1016/j.enconman.2005.04.013

Google Scholar

[2] M. Fatouh and M. El Kafafi, Assesment of propane/commercial/butane mixtures as possible alternatives to R134a in domestic refrigerators, Energy Convers. Manage. 47 (2006) 2644-2658.

DOI: 10.1016/j.enconman.2005.10.018

Google Scholar

[3] D.S. Jung and R. Radermacher, Performance simulation of single-evaporator domestic refrigerators charged with pure and mixed refrigerants, Int. J. Refrig. 14 (1991) 223-232.

DOI: 10.1016/0140-7007(91)90007-4

Google Scholar

[4] M. Mohanraj, S. Jayaraj, C. Muraleedharan and P. Chandrasekar, Experimental investigation of R290/R600a mixture as an alternative to R134a in a domestic refrigerator, Int. J. Therm. Sci. 48 (2009) 1036-1042.

DOI: 10.1016/j.ijthermalsci.2008.08.001

Google Scholar

[5] M. Rasti, S.F. Aghamiri and M.S. Hatamipour, Energy efficiency enhancement of a domestic refrigerator using R346A and R600a as alternative refrigerants to R134a, Int. J. Therm. Sci. 74 (2013) 86-94.

DOI: 10.1016/j.ijthermalsci.2013.07.009

Google Scholar

[6] J.S. Brown, S.F. Yana-Motta and P.A. Domanski, Comparative analysis of an automotive air conditioning system operating with CO2 and R134a, Int. J. Refrig. 25 (2002) 19-32.

DOI: 10.1016/s0140-7007(01)00011-1

Google Scholar

[7] O. Brunin, M. Feidt, B. Hivet, Comparison of the working domains of some compression heat pumps and a compression-absorption heat pump, Int. J Refrig. 20 (1997) 308-318.

DOI: 10.1016/s0140-7007(97)00025-x

Google Scholar