Effect of Preparation on Standard Dry Density and Strength of Foamed Cement by Orthogonal Test
Abstract:
In this paper, we studied the effect of preparation on standard dry density and strength of foamed cement by orthogonal test. The results indicate that the more excellent combination is A1B1C1, namely G1, the standard dry density is 376 kg/m3, the flexural and compressive strengths are 0.43 MPa and 0.8 MPa respectively, and the thermal conductivity is 0.074 W/(m·K), which conforms to the characteristics of light weight and high strength. Fewer Ca (OH)2 crystals and more C-S-H gel generated in G1 through scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis is the reason for its high strength.