Numerical Study on the Static Response of Grouting-Sleeve Reinforcement-Connection Component with Different Sleeve-Rib Space
Abstract:
According to the actual structure, the ABAQUS finite element models of grouting-sleeve reinforcement-connection component with different sleeve-rib space were established, and the mechanical performance of component under the action of axial tension load was studied. Meanwhile, the stress distributions among sleeve with six kinds of sleeve-rib space by means of stress nephogram were obtained. Numerical simulation result shows that with the sleeve-rib space decreasing from 56mm to 8mm, the constraint capability of grouting material on reinforcement is better and better, and the internal force distribution in sleeve tends to be more homogeneous.