Earthquake Mitigation Effect Analysis of Hysteretie DamPers in Steel Frame

Article Preview

Abstract:

This paper analyses the frame without mild steel dampers and the frame installed the new T-type , box –type and S-type mild steel dampers by FEM ABAQUS. The results shows the frame installed the new mild steel dampers have smaller yield displacement and the fuller hysteresis curve at low cyclic load, but the initial stiffness, yield strength , stiffness after yielding are greater. Research shows that the new type mild steel dampers have good energy performance, and have the better effect to seismic framework.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1767-1770

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] ZHOU Yun. JINSHU HAONENG JIANZHEN JIEGOU SHEJI[M]WU Han: Wuhan University of Technology Press, 2006: 1(In Chinese).

Google Scholar

[2] WANG Shuang. Parametic analysis and seismic performance of new Perforated H-shaped steel damper. Guangzhou university, 2012. 5(In Chinese).

Google Scholar

[3] LUO Chunfeng, SHI Weixing, GAO Xi. Shock Absorption Analysis of High - rise ReinforcedConcrete Framework with Mild Steel Damper. ournal of Jiamusi University ( Natural Science Edition), 2012. 5(In Chinese).

Google Scholar