The Analysis of Hysteretic Behavior of Concrete Filled Double Skin Steel Tubular after Exposure to Fire

Article Preview

Abstract:

In recent years,frequent fires and earthquake make the buildings damage badly,and it causes huge economic loss. Concrete filled double skin steel tubular (Hereinafter referred to as CFDST) as a new member of structure,its mechanical properties are similar to concrete filled steel tubular,at the same time has better fire performance and seismic capacity. Based on this background,the paper expounds study the mechanical performance of CFDST is very important,the hysteretic behavior is the main mechanical indexes of the seismic performance of CFDST after exposure to fire. The study of it will fill the new component in the blank of seismic performance research.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2675-2678

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Hong Huang. Behavior of concrete filled double-skin steel tubular beam-column[D]. Fuzhou, Fuzhou univorcity, (2006).

Google Scholar

[2] Xuejia Chen, Hong Huang, Chen Huang. Study on the model of hysteretic behavior of concrete rete-filled double skin (CHS inner and CHS outer) steel tubular beam-column[J]. Railway Construction, 2011, 141-144.

DOI: 10.1016/j.tws.2004.03.017

Google Scholar

[3] Lin-Hai Han, Zhong Tao, Hong Huang, Xiao-Ling Zhao. Concrete-filled double skin (SHS outer and CHS inner) steel tubular beam-columns [J]. Thin-walled Structures, 2004, 42(9): 1329 -1355.

DOI: 10.1016/j.tws.2004.03.017

Google Scholar

[4] Lin-Hai Han. Concrete filled steel tube structure—theory and practice[M]. Beijing, Science Press, (2006).

Google Scholar

[5] Johnson R P. Some research on composite structures in the U. K. 1960-1985. Proc. of an Engineering Foundation Confer. on Steel-Concrete Composite Structures, ASCE. Irsee, 1996. 15-25.

Google Scholar

[6] Roik E H K. Review of the development of composite structures in Germany. Proc. of an Engineering Foundation Confer. on Steel-Concrete Composite Structures, ASCE. Irsee, 1996. 55-74.

Google Scholar

[7] Youfu Yang, Lin-Hai Han. Fire behavior of concrete-filled double skin (CHS inner and CHS outer) steel tubular columns[J]. Journal of Harbin Institute of Technology, 37(S1), 2005: 400-403.

DOI: 10.1016/j.jcsr.2003.11.008

Google Scholar

[8] Yang Y F, Han L H. Concrete-filled double-skin tubular columns under fire [J]. Magazine of Concrete Research, 2008, 60(2): 211-222.

DOI: 10.1680/macr.2007.00074

Google Scholar

[9] Xin Yu, Zhong Tao. Residual strength of concrete-filled double skin steel tubular stub columns after exposure to fire[J]. Industrial building, 39(4), 2009: 9-13.

Google Scholar