Modeling Simulation of Single-Phase Arc Grounding in Neutral Un-Effectual Grounding Power System Based on Matlab

Article Preview

Abstract:

Generally in China, the power distribution networks below 35kV level are Neutral un-effectual grounding systems. Single-phase electric arc grounding failure takes up the majority of neutral un-effectual grounding power system failures. However, it is a very complex process to deal with arc fault so that establishing a mathematical model for arc becomes challenging. Matlab Simulink was hence utilized to establish arc simulation model. Comparisons were made between the ideal wave form and the result based on the single phase arc grounding fault simulation to test the validity of the model, which shows good consistency.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

3017-3020

Citation:

Online since:

August 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] YAO Huan-nian. Resonance grounding on power system[M]. Beijing: China Electric Power Press, (2009).

Google Scholar

[2] DJURIC M B, TERZIJA V V. A new approach to the arcing faults detection for fast autoreclosure in transmission systems[J]. IEEE Transactions on Power Delivery. 1995, 10(4): 1793-1798.

DOI: 10.1109/61.473378

Google Scholar

[3] JOHN SAT, AGGARWAL R K, SONG Y H. Improved techniques for modeling fault arcs on faulted EHV transmission systems, [J]. IEE Proceedings—Generation, Transmission and Distribution, 1994, 141(2): 148-154.

DOI: 10.1049/ip-gtd:19949869

Google Scholar

[4] M. Kizilcay and T. Pniok, Digital simulation of fault arcs in power systems, Eur. Trans. Elect. Power , vol. 1, no. 1, Jan. /Feb. (1991).

DOI: 10.1002/etep.4450010111

Google Scholar

[5] ELKALASHY N I, LEHTONEN M. Modeling and experimental verification of high impedance arcing fault in medium voltage networks [J]. IEEE Trans. on Dielectrics and Electrical Insulation, 2007, 14(2): 375-383.

DOI: 10.1109/tdei.2007.344617

Google Scholar

[6] WANG Yan-song, XIE Fei. Simulation and analysis of single phase to ground fault in distribution networks [J]. High Voltage Engineering, 2008, 34(1): 123-127.

Google Scholar

[7] ELKALASHY N I, LEHTONEN M. Modeling and experimental verification of high impedance arcing fault in medium voltage networks [J]. IEEE Trans. on Dielectrics and Electrical Insulation, 2007, 14(2): 375-383.

DOI: 10.1109/tdei.2007.344617

Google Scholar