A Calculation Method of Transformer Fault BPA Based on Spatial Interpolation and IEC60599

Article Preview

Abstract:

The diagnostic conclusions by IEC60599 gas ratio method cannot be directly applied to DS Evidence Theory for information fusion. In order to solve the problem, this research proposed a calculation method for transformer fault BPA based on spatial interpolation. Firstly, the fault characteristic space defined by IEC60599 gas ratio method was analyzed. Based on the analysis results, the entire fault characteristic space was divided into several rectangular units through spatial discretization. Next, the BPA function of faults in each unit was formulated by 8-node hexahedral unit interpolation. In this way, the continuous BPA function of faults in the entire space was obtained. This method not only met the requirements of BPA function but also enabled the numerical reflection of various fault possibilities in the calculation results. Thus, this method extended the application of IEC60599 gas ratio method. With example calculation, the correctness and feasibility of this method in actual engineering projects were verified.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

563-567

Citation:

Online since:

September 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Y. Shang, C.J. Yan, Z. Yan. Synthetic Insulation Fault Diagnostic Model of Oil-immersed Power Transformers Utilizing Information Fusion. Proceedings of the CSEE, Vol. 22, No. 7, (2002), pp.115-118.

Google Scholar

[2] Z.X. Gao, C.X. Guo, B. Yu. Study of a fault diagnosis approach for power grid with information fusion based on multi-data resources. Power System Protection and Control, Vol. 39, No. 6, (2011), pp.17-23.

Google Scholar

[3] B.Y. Kang, Y. Li, Y. Deng. Determination of Basic Probability Assignment Basedon Interval Numbers and Its Application. ACTA ELECTRONICA SINICA, Vol. 40, No. 6, (2012), pp.1092-1096.

Google Scholar

[4] J. Yang, L. Tian, A.J. Zhao. Approach for Constructing the Confidence Function Distribution of Evidence Theory Based on Typical Sample. Journal of North China Electric Power University, Vol. 34, No. 5, (2008), pp.70-72.

Google Scholar

[5] D.Q. Han. Multiple Classifiers Fusion Based on Weighted Evidence Combination. IEEE International Conference on Automation and Logistics. Jinan, China: IEEE, (2007), pp.2138-2143.

DOI: 10.1109/ical.2007.4338929

Google Scholar

[6] IEC-60599,Mineral oil-impregnated electrical equipment in service- guide to the interpretation of dissolved and free gases Analysis.

DOI: 10.3403/01663710u

Google Scholar

[7] X.C. Wang. The Finite Element Method. Tsinghua University Press, Beijing, China, (2003).

Google Scholar

[8] X.F. Kong, J. Li. Analysis and Treatment of Abnormal Chromatographic Result Fault in 220kV Main Transformer. Transformer, Vol. 49, No. 6, (2012), pp.61-64.

Google Scholar