Simulation and Correction of the Slice Profile Based on SLR Theory in a 0.35 T Permanent MRI System

Article Preview

Abstract:

To locate the imaging slice, the hydrogen protons within the selected slice are excited by the coaction of radio-frequency pulse (RF pulse) and slice-selection gradient during the process of magnetic resonance imaging (MRI). However, the absolute consistency of the time between the RF transmitting system and gradient system can’t be guaranteed in an actual magnetic resonance system, which makes the slice profile not ideal enough. Imperfect slice profile will lead to poor imaging quality. In this paper, Shinnar-Le Roux (SLR) theory is used to simulate the slice profile with different relative delays between RF and slice-selection gradient to solve this problem. By matching the actual slice profile with the simulation results, the relative delay is measured in an actual 0.35T permanent magnet MRI system. The practicability of the method is verified for the improvement of image quality after applying the measured delay to correct the actual MRI system.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

4581-4586

Citation:

Online since:

September 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] P.M. Joseph, L. Axel, Potential problems with selective pulses in NMR imaging systems, Medical Physics. 11 (1984) 772-777.

DOI: 10.1118/1.595579

Google Scholar

[2] D. Hoult., NMR imaging rotating frame selective pulses, Journal of Magnetic Resonance, 38(1980)369-374.

DOI: 10.1016/0022-2364(80)90289-9

Google Scholar

[3] M. Silver, R. Joseph, D. Hoult, Selective pulse creation by inverse solution of the Bloch-Riccati equation, in Proc. 2nd SMRM. (1983)22.

Google Scholar

[4] D. Hoult, the solution of the Bloch equations in the presence of a varying B1 field: An approach to selective pulse analysis, Magnet. Resonance Med. 35(1979) 66-88.

DOI: 10.1016/0022-2364(79)90078-7

Google Scholar

[5] M. Shinnar, S. Eleff, H. Subramanian, J.S. Leigh, The synthesis of pulse sequences yielding arbitrary magnetization vectors, Magnet. Resonance Med. 12 (1989) 74-80.

DOI: 10.1002/mrm.1910120109

Google Scholar

[6] M. Shinnar, L. Bolinger, J.S. Leigh, The use of finite impulse response filters in pulse design, Magnet. Resonance Med. 12 (1989) 75-87.

DOI: 10.1002/mrm.1910120110

Google Scholar

[7] M. Shinnar, J.S. Leigh, The application of spinors to pulse synthesis and analysis, Magnet. Resonance Med. 12 (1989) 93-98.

DOI: 10.1002/mrm.1910120112

Google Scholar

[8] J.E. Holmes, G.M. Bydder, MR imaging with ultrashort TE(UTE) pulse sequences. Basic principles, Radiography. 11(2005) 639-645.

DOI: 10.1016/j.radi.2004.07.007

Google Scholar