Assessment of Reliability and Overall Life-Time of the Turbo Generator in the Kamýk Power Station

Article Preview

Abstract:

This paper presents the results of measurement of the stress and the theoretical analysis of the steel structure of the Kaplan turbo generator in the Kamýk power station in the Czech Republic. Based on the number of load cycles and the finding of the maximum stress range of critical details of the most loaded part, the lower star, the residual lifetime of the turbo generator was determined.