Design of a High-Voltage Signal Generator Applied Flashover Fault Detection
Abstract:
For cable flashover failure, a signal generator design ideas of the NC DC high flash - DC medium voltage flash - low-voltage flash based on three pulse method, consists of three components: the DC source, medium-high pressure unit and low pressure unit. DC source adopts AC 220V power supply, after rectification, chopping booster output. The output of the DC source through an inverter and high-frequency boost get the high-voltage unit. Low unit through the high-speed switching devices and capacitor charging and discharging achieve nanosecond pulse generation. In this paper, the various aspects of the design of the system have made a detailed description and simulation research.