Evaluation Method for Energy Saving Effect of Reflective Thermal Insulation Coatings

Article Preview

Abstract:

According to the climate and energy saving characteristics in the hot summer and cold winter zone, especially in view of requirements for thermal insulation in summer, reflective thermal insulation coatings (RTIc) are gradually applied in building energy efficiency of exterior envelope. A feasible evaluation method for energy saving effect is very important for acceptance of energy efficient building construction. In this paper, thermal resistance has been used as the evaluation index. The energy efficiency of the reflective thermal insulation coatings was investigated. Four hot boxes were applied contrast test. Based on the qualitative and quantitative analysis of electricity consumption within 36 hours and comparative analysis of heating process simulating sunlight environment, thermal resistance of RTIc can be calculated on the basis of the correlation between power saving rate and thermal resistance so that energy saving effect of RTIc can be quantitatively characterized.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2348-2353

Citation:

Online since:

March 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Y. WANG, Z. HUANG, et al. Cost- effectiveness assessment of insulated exterior walls of residential buildings in cold climate[J]. International Journal of Project Management. 2007, 25(2): 143-149.

DOI: 10.1016/j.ijproman.2006.09.007

Google Scholar

[2] N. GHRAB-MORCOS. CHEOPS: a simplified tool for thermal assessment of Mediterranean residential buildings in hot and cold seasons[J]. Energy and Buildings. 2005, 37(6): 651-662.

DOI: 10.1016/j.enbuild.2004.09.020

Google Scholar

[3] M. S. MOHSEN, B. A. AKASH. Some prospects of energy savings in buildings[J]. Energy Conversion and Management. 2001, 42(11): 1307 –1315.

DOI: 10.1016/s0196-8904(00)00140-0

Google Scholar

[4] S. A. MOHAMMAD. Performance characteristics and practical applications of common building thermal insulation materials[J]. Building and Environment. 2005, 40(3): 353-366.

DOI: 10.1016/j.buildenv.2004.05.013

Google Scholar

[5] Santamouris M,Pavlou K,Synnefa A,et a1.Recent progress on passive cooling techniques advanced technological developments to improve survivability levels in low-income households [J]. Energy and Buildings. 2007, 39:859-866.

DOI: 10.1016/j.enbuild.2007.02.008

Google Scholar

[6] Guo Weilin,Lu Guohao,Ho Chao. Study on Energy Saving Effect of Heat-reflective Insulation Coating on Exterior Walls of Building in Summer [J]. Construction Technology. 2010, 39(7).

DOI: 10.4028/www.scientific.net/amm.71-78.3657

Google Scholar

[7] P. Berdahl. Pigments to reflect the infrared radiation from fire[J]. Journal of Heat Transfer. 1995, 117: 355-358.

DOI: 10.1115/1.2822529

Google Scholar

[8] Jams M. Abrige,P. E, High, Albedo. Roof coatings impact on energy consumption. ASHRAE Transactions. 1998, 5: 957-987.

Google Scholar

[9] Danny S. Parker, Stephen F. Barkaszl. Roof solar reflectance and cooling energy use: field research results from Florida[J]. Energy and Buildings. 1997, 25.

DOI: 10.1016/s0378-7788(96)01000-6

Google Scholar

[10] Paul Berdahl. Building energy efficiency and fire safety aspects of reflective coatings[J]. Energy and Buildings. 1995, 22: 187-191.

DOI: 10.1016/0378-7788(95)00921-j

Google Scholar

[11] David W. Yarbrough. Use of radiation control coatings to reduce building air-conditioning loads[J]. Energy Source. 1993, 15(1): 59-66.

DOI: 10.1080/00908319308909011

Google Scholar

[12] Lazaros Elias Mavromatidis, Mohamed El Mankibi , Pierre Michel. Advances in Building Energy Research[J]. Taylor & Francis. volume 5, (2011).

Google Scholar

[13] T. Soubdhan, T. Feuillard, F. Bade. Experimental evaluation of insulation material in roofing system under tropical climate[J]. Solar Energy. Volume 79, Issue 3, September (2005).

DOI: 10.1016/j.solener.2004.10.009

Google Scholar

[14] Frédéric Miranville, Ali Hamada Fakra, Stéphane Guichard. Evaluation of the thermal resistance of a roof-mounted multi-reflective radiant barrier for tropical and humid conditions: Experimental study from field measurements[J]. Energy and Buildings. Volume 48, May (2012).

DOI: 10.1016/j.enbuild.2012.01.013

Google Scholar

[15] ASHRAE Handbook—Fundamentals[M]. (2009).

Google Scholar

[16] Xu Bin, Ye Hong, Zhang Chengmei. Numerical simulation on the dynamic air-conditioning load of the top floor building with thermal insulation coatings[J]. Acta energiae solaris sinica, Jul, 2008, Vol. 29. No. 7.

Google Scholar

[17] GB/T25261-2010, 《Solar heat reflecting insulation coatings for buildings》[S].

Google Scholar

[18] JG/T 235-2008,《Architecture reflective thermal insulation coatings》[S].

Google Scholar

[19] JC/T 1040-2007,《Exterior reflective thermal insulating coatings on building》[S].

Google Scholar

[20] ASTM C1483-04, 《Standard Specification for Exterior Solar Radiation Control Coatings on Buildings》[S].

Google Scholar