Seismic Performance of the Masonry Buildings with Frame at the Bottom Equipped with the New Hybrid Damper

Article Preview

Abstract:

An improved new damper was presented. The mechanical properties of the damper were conducted by the numerical simulation method under the cyclic loading. Also, the seismic mitigation effectiveness of the damper was verified though Time History Analysis. The results show that the improved damper has good hysteretic behavior. It can significantly reduce structural displacement response. Furthermore, the seismic performance of Masonry Buildings with Frame at the Bottom was studied by equipped the improved damper. The control effect was compared with Masonry Buildings with Frame at the Bottom and Masonry Buildings with Two-story Frame at the Bottom.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

905-910

Citation:

Online since:

March 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] V. Torraa, A. Isalguea, F. Martorella, P. Terriaultb, F.C. Loveyc. Built in dampers for family homes via SMA: An ANSYS computation scheme based on mesoscopic and microscopic experimental analyses[J]. Engineering Structures, 29 (2007) 1889-(1902).

DOI: 10.1016/j.engstruct.2006.08.028

Google Scholar

[2] Liu, D. _2005_Analysis and design of steel framed buildings with shape memory alloy wire damper[J]. MS thesis, Lehigh Univ., Bethlehem, Pa.

Google Scholar

[3] BassemAndrawes, A.M. ASCE; and Reginald DesRoches, A.M. ASCE•Comparison between Shape Memory Alloy Seismic Restrainers and Other Bridge Retrofit Devices[J]•Journal of Bridge Engineering( 2007), 12(6): 700-709.

DOI: 10.1061/(asce)1084-0702(2007)12:6(700)

Google Scholar

[4] Wenhui Wei, Weilian Liao, Zhe'an Lu. Using VFD for seismically retrofitting of hybrid masonry-concrete structures[J]. Earthquake engineering and Engineering Vibration (2002), 22(2): 154-157. In Chinese.

Google Scholar

[5] Conglv Qing, Aihui Zhang. Nonlinear time history analysis of brick masonry buildings with pilot-story retrofitted by energy-absorption unbounded steel brasses cased in concrete(2005), 26(4): 58-63. In Chinese.

Google Scholar

[6] Gui, S,L. SMA Passive Damping Methods of Seismic Resistance of Civil Engineering Structures and its Applications. Journal of Taiyuan University of Technology (2001)., 32: 2, 112-119. In Chinese.

Google Scholar

[7] Hui,L. and Chen, X,M. Experimental investigation of earthquake response reduction of buildings with added two types of SMA passive energy dissipation devices. Earthquake engineering and Engineering Vibration (2003), 23: 1, 133-139, In Chinese.

Google Scholar

[8] Su, D,X. Xiao, F, B,. and Bin, S,L. A new type of shape memory alloy damper. Journal of Structure Building(2005), 26: 3, 44-49. In Chinese.

Google Scholar

[9] Su, D,X. Li, W, and Peng,Z. Design and performance study of a SMA incorporated friction damper. WORLD EARTHQUAKE ENGINEERING (2006), 22: 2, 1-6. In Chinese.

Google Scholar

[10] Yuan,Y. Qi, C, Y,. andAi, R,L. A new type of shape memory alloy(SMA)-fluid viscous damper. Journal of Guangzhou University (Natural Science Edition)(2008), 7: 2, 91-94. In Chinese.

Google Scholar

[11] Graesser E J. and Cozzarelli F, A. Shape memory alloys as new materials for a seismic isolation. ASCE, Journal of Engineering Mechanics (1991), 117: 11, 2590-2608.

DOI: 10.1061/(asce)0733-9399(1991)117:11(2590)

Google Scholar