Thermal Enhancement in Tubes with Dual Twisted Tapes

Article Preview

Abstract:

Influence of the dual twisted tapes (DTs) on the heat transfer enhancement in a circular tube is reported. The effects of twist ratio (y/w = 2.0, 3.0 and 4.0) on the heat transfer rate, friction factor, and thermal performance factor in a tube under constant wall heat flux were investigated in turbulent regions. Computations, based on a finite volume method, and the SIMPLE algorithm, were carried out by QUICK schemes. From the numerical results, heat transfer rate and pressure loss increased as twist ratio of tape (y/w) decreased. Based on the same pumping power consumption, the optimum thermal performance was achieved by the use of the tapes with twist ratio of 3.0. In addition, the predictions of flow-thermal phenomena (streamline, velocity vector, TKE and local Nusselt number) are also described.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

239-244

Citation:

Online since:

April 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] S. Jaisankar, T.K. Radhakrishnan and K.N. Sheeba, Experimental studies on heat transfer and friction factor characteristics of thermosyphon solar water heater system fitted with spacer at the trailing edge of twisted tapes, Applied Thermal Engineering 29 (2009).

DOI: 10.1016/j.applthermaleng.2008.06.009

Google Scholar

[2] S. Jaisankar, T.K. Radhakrishnan and K.N. Sheeba, Experimental studies on heat transfer and thermal performance characteristics of thermosyphon solar water heating system with helical and left-right twisted tapes, Energy Conversion and Management 52 (2011).

DOI: 10.1016/j.enconman.2010.11.024

Google Scholar

[3] D.R. Waghole, R.M. Warkhedkar, V.S. Kulkarni and R.K. Shrivastva, experimental investigations on heat transfer and friction factor of silver nanofliud in absorber/receiver of parabolic trough collector with twisted tape inserts, Energy Procedia 45 (2014).

DOI: 10.1016/j.egypro.2014.01.060

Google Scholar

[4] Y.R. Sekhar, K.V. Sharma, R.T. Karupparaj and C. Chiranjeevi, Heat transfer enhancement with Al2O3 nanofluids and twisted tapes in a pipe for solar thermal applications, Procedia Engineering 64 (2013) 1474-1484.

DOI: 10.1016/j.proeng.2013.09.229

Google Scholar

[5] J. Ananth and S. Jaisankar, Experimental studies on heat transfer and friction factor characteristics of thermosyphon solar water heating system fitted with regularly spaced twisted tape with rod and spacer, Energy Conversion and Management 73 (2013).

DOI: 10.1016/j.enconman.2013.04.022

Google Scholar