Transient Instantaneous Voltage Sag of Distributed Generation Bus in Muangxay Substation, Oudomxay Province, Laos

Article Preview

Abstract:

This paper presents the transient instantaneous voltage sag analysis of distributed generation (DG) in distribution system. The behavior of voltage sag is analyzed by using DigSILENT power factory software (DPFS). As affected by unsymmetrical fault of feeder 2, the calculation of initial condition carries out through instantaneous values (electromagnetic transients). The simulation results show that instantaneous voltage sag affects the DG and operation of electrical equipment. The phase short circuit affects the voltage waveform, varies from the original waveform and caused the flicker transient problem.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1170-1174

Citation:

Online since:

April 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Z. Lidong and M. Bollen, Characteristic of voltage dips (sags) in power systems, IEEE T. Power Deliv. 15 (2000) 827-832.

DOI: 10.1109/61.853026

Google Scholar

[2] M. Mansor and N.A. Rahim, Voltage sag detection-A survey, TECHPOS International Conference, (2009) 1-6.

DOI: 10.1109/techpos.2009.5412088

Google Scholar

[3] F.M. Jong and S.K. Jin, Voltage sag analysis in loop power distribution system with FSCL, IEEE Trans on applied superconductivity, 23 (2013) 5601504.

DOI: 10.1109/tasc.2013.2238374

Google Scholar

[4] M. Yan and G. Karady, A single-phase voltage sag generator for testing electrical equipment, T&D IEEE/PES conference, (2008) 1-5.

DOI: 10.1109/tdc.2008.4517185

Google Scholar

[5] A. Felce, G. Matas and Y. Dasilva, Voltage sag analysis and solution for an industrial plant with embedded induction motors, AIS annual meeting conference 39th, (2004) 2573-2578.

DOI: 10.1109/ias.2004.1348838

Google Scholar

[6] T. Tayjasanant and S. Surisunthon, Impact of distributed generation on voltage sag in Thailand's distribution systems, Harmonics and quality of power (ICHQP), IEEE 15th, (2012) 624-629.

DOI: 10.1109/ichqp.2012.6381238

Google Scholar

[7] IEEE Recommended Practice for Monitoring Electric Power Quality, IEEE Std. 1159-(2009).

Google Scholar

[8] M. Bollen, D. Sabin and R. Thailam, Voltage-sag indices – recent developments, IEEE P1564 Task Force, I Symposium CIGRE/IEEEPES on Quality and security of electric delivery systems. (2003) 34-41.

DOI: 10.1109/qsepds.2003.159792

Google Scholar