Experimental Study of Splitting Tensile Strength of Polymer Resin Grout with Fly Ash

Article Preview

Abstract:

Polymer resin grout can be used as bonding material for grouted sleeve connections This paper presents the experimental results on the effectiveness of fly ash as micro filler to the splitting tensile strength of polymer grout. In addition, the cement grout that is usually used as bonding material had been tested for comparison. Eleven proportions, of fly ash as the filler and polymer as binder, were tested with the binder to filler volume ratios of 1:1 and 1:1.5. The test results revealed that fly ash can be used as a micro-filler material to partially replace ordinary river sand in polymer resin grout. The splitting tensile strength of the polymer grout increases with the increase of fly ash contents. However, for higher level of fly ash of more than 22%, the splitting tensile strength deteriorated. For binder: filler ratio of 1:1, the optimum fly ash content of 22% gave the maximum splitting strength of 17.62 MPa, which can be considered acceptable for producing grout with high strength bonding material.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

38-42

Citation:

Online since:

September 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] A. B. A. Rahman, J. H. Ling, M. H. Osman, S. Mohammad, A. A. Saim, Development of splice connections for precast concrete structures, AMR 980 (2014) 132-136.

DOI: 10.4028/www.scientific.net/amr.980.132

Google Scholar

[2] P. G. Gambarova, G. Rosati, Bond and splitting in reinforced concrete: test results on bar pull-out, Mater. Struct. 29 (1996) 267-276.

DOI: 10.1007/bf02486361

Google Scholar

[3] R. Tepfers, Cracking of concrete cover along anchored deformed reinforcing bars. Mag. Concrete Res. 31 (1979) 3-12. ‏‏.

DOI: 10.1680/macr.1979.31.106.3

Google Scholar

[4] H. W. Reinhardt, Bond of steel to strain-softening of concrete taking account of loading rate, FRAMCOS (1992) 809-820.

Google Scholar

[5] A. Alias, M. A. Zubir, K. A. Shahid, A. B. A. Rahman, Structural performance of grouted sleeve connectors with and without transverse reinforcement for precast concrete structure, Procedia Eng. 53 (2013) 116-123. ‏‏.

DOI: 10.1016/j.proeng.2013.02.017

Google Scholar

[6] J. Raymond, B. Sauntson, Resins and polymers for grouts, concrete and filled systems-A wide perspective, in Proc., 5th Int. Congress on Polymers in Concrete, (1987) 27-31.

Google Scholar

[7] S. M. Shivasharan, Polymer coatings, Proc., Vol. ll, 3rd Int. Congr. on polymers in concrete, Nihon Univ., The Nihon Univ. Ctr. for Res. Coordination and PIng., Japan (1981) 1347-1363.

Google Scholar

[8] V. Navaratnarajah, Splicing of reinforcement bars with epoxy joints, Int. J. Adhes. Adhes. 3 (1983) 93-99. ‏‏.

Google Scholar

[9] E. Petrie, Epoxy adhesive formulations: McGraw Hill Professional, (2005).

Google Scholar

[10] T. Goulding, Epoxy resin adhesives, in: Pizzi A., Mittal KL Handbook of adhesive technology, New York: Marcel Dekker Inc, 2003, p.823–838.

Google Scholar

[11] K. Koushfar, A. B. A Rahman, Y. Ahmad, M. H. Osman, Bond behavior of the reinforcement bar in glass fiber-reinforced polymer connector, Građevinar. 66 (2014) 301-310. ‏‏ ‏.

Google Scholar

[12] S. J. A. Hosseini, A. B. A. Rahman, Analysis of spiral reinforcement in grouted pipe splice connectors, Građjevinar 65 (2013) 537-546.

Google Scholar

[13] ASTM C 469, Standard test method for splitting tensile strength of cylindrical concrete specimens, American Society of Testing and Materials (1996).

Google Scholar