Development of Novel Fire Alarm Warning System Using Automated Remote Messaging Method

Article Preview

Abstract:

This paper discussed on design and development of fire warning system using automated remote messaging method. This device enables to alert the owner whenever fire occur that need rapid attention towards the building. This is maybe due to carelessness of user or gas leakage. Fire warning system is an existing project but it will be enhanced. This project discussed the design and implementation of a fire alarm system using the microcontroller which controlled the entire system. This system comprised of smoke detector that linked to PIC and GSM Modem. When smoke detected, the fire alarm will triggered and send a signal to the PIC. The PIC will process the data and transmit the signal to the GSM modem. The GSM modem will send message to alert the building owner. The owner can make further action by informing the nearest fire department. This module is applied for transferring of GSM SMS message to the owner mobile number. The devices can be the early and fast prevention system for building owner.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

578-584

Citation:

Online since:

September 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] N. Zarka, I.A. Housi, M. Akhkobek, Temperature control via SMS, (2006).

Google Scholar

[2] T. Begum, M.S. Hossain, M.B. Uddin, M.S.H. Chowdhury, Design and development of activation and monitoring of home automation system via SMS through microcontroller, International IEEE Conference on computers and devices for communication, (2009).

Google Scholar

[3] Application of GSM/GPRS Modems, Accessed 12 June 2008, www. ravirajtech. com/Applications_of_GSM_Modem. html.

Google Scholar

[4] C. I Ming, Industrial Alarm System with PIC, B.E. thesis, Universiti Teknikal Mlaysia Melaka, (2003).

Google Scholar

[5] T.K. Lim, Alarm system using PIC. B.E. thesis, Universiti Kebangsaan Malaysia, (2001).

Google Scholar

[6] Vougioukas S. & Roumeliotis M. A system for basic-level network fault management based on the GSM Short message service (SMS).

DOI: 10.1109/eurcon.2001.937799

Google Scholar

[7] Dogan. I, Advance PIC Microcontroller Projects in C: From USB to RTOS with the PIC 18F Series: Newnes, (2008).

Google Scholar

[8] Cady, F. M., Microcontrollers and microcomputers, Principles of software and hardware engineering. New York Oxford: Oxford University Press, (1997).

Google Scholar

[9] Duarte, L. A., The microcontroller beginner's handbook (Vol. 2). Howard W. Sams and company, (1998).

Google Scholar

[10] Md Sani, Z., Noordin, A., Mohammed Kassim, E. A., & Hj Shukor, A. Z. Microcontroller Technology, Universiti Teknikal Malaysia Melaka, 2011/(2012).

Google Scholar

[11] Wang. X. X and Jianmei, Bao Minzhong, Multi- sensor fire alarm detection algorithm for ship fire alarm system using Neural Fuzzy Network, 5th International Conference on signal processing. Vol 3, Tech. Rep. 1602-1605, August 21-25, (2000).

DOI: 10.1109/icosp.2000.893407

Google Scholar