Scintillation Properties of Ce-Doped LuYAP Crystal for Gamma Ray Detection

Article Preview

Abstract:

In the present day, inorganic scintillating crystals become a main part in detection and spectroscopy of nuclear particles and high energy photons, more spectively in X/g-ray imaging. The good properties for the scintillating crystals used in these applications require high photon yield, high stopping power, good energy resolution, good light yield proportionality, and minimal afterglow. The main useful of Ce-doped Lu0.7Y0.3AlO3 (LuYAP(Ce)) are high stopping power and non-hygroscopic which are expected to be key ingredients for medical imaging. In this work, we studied the light yield non-proportionality and energy resolution of LuYAP(Ce) crystal with the energy range from 31 to 1,274.5 keV using photomultiplier tube (PMT) readout. The intrinsic resolution of the LuYAP(Ce) crystal has been determined after correcting the measured PMT resolution. The results showed that the non-proportional response of the crystals was strongly correlated with the intrinsic resolution of the crystals.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

93-96

Citation:

Online since:

October 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] J.A. Mares, M. Nikl, J. Chval, I. Dafinei, P. Lecoq, J. Kvapil, Fluorescence and scintillation properties of LuAlO3: Ce crystal, Chem. Phys. Lett. 241 (1995) 311-316.

DOI: 10.1016/0009-2614(95)00677-v

Google Scholar

[2] A. Annenkov, A. Fedorov, M. Korzhik, P. Lecoq, O. Missevitch, First results on prototype production of new LuYAP crystals, Nucl. Instum. Methods Phys. Res. A 527 (2004) 50-53.

DOI: 10.1016/j.nima.2004.03.016

Google Scholar

[3] L. Gerward, N. Guilbert, K.B. Jensen, H. Levring, WinXCom-a program for calculating X-ray attenuation coefficients, Radiat. Phys. Chem. 71 (2004) 653-654.

DOI: 10.1016/j.radphyschem.2004.04.040

Google Scholar

[4] Z. Guzik, S. Borsuk, K. Traczyk, M. Plominski, TUKAN-an 8k pulse height analyzer and multi-channel scaler with a PCI or a USB interface, IEEE T. Nucl. Sci. 53 (2006) 231-235.

DOI: 10.1109/tns.2006.869819

Google Scholar

[5] M. Moszynski, M. Kapusta, M. Mayhugh, D. Wolski, S.O. Flyckt, Absolute light output of scintillators, IEEE T. Nucl. Sci. 44 (1997) 1052-1061.

DOI: 10.1109/23.603803

Google Scholar

[6] M. Kapusta, M. Balcerzyk, M. Moszynski, J. Pawelke, A high-energy resolution observed from a YAP: Ce scintillator, Nucl. Instrum. Methods Phys. Res. A 421 (1999) 610-613.

DOI: 10.1016/s0168-9002(98)01232-7

Google Scholar

[7] M. Moszynski, J. Zalipska, M. Balcerzyk, M. Kapusta, W. Mengeshe, J.D. Valentine, Intrinsic energy resolution of NaI(Tl)1, Nucl. Instrum. Methods Phys. Res. A 484 (2002) 259-269.

DOI: 10.1016/s0168-9002(01)01964-7

Google Scholar

[8] P. Dorenbos, Light output and energy resolution of Ce3+-doped scintillators, Nucl. Instrum. Methods Phys. Res. A 486 (2002) 208-213.

Google Scholar