CFD Analysis on Thermal Comfort and Indoor Air Quality Affected by Partitions in Air-Conditioned Building

Article Preview

Abstract:

This paper presents a CFD analysis on thermal comfort and indoor air quality affected by partitions in an air-conditioned building. CFD experiments are carried out to simulate variables of indoor air before/after installation or removal of partitions. Accordingly, the Predicted Mean Vote (PMV) is determined as an indicator of thermal comfort while the carbon dioxide concentration within an air-conditioned space is used for the assessment of indoor air quality. Some simulated results are validated by measurements with good agreement where a case study is conducted in an air-conditioned space of a library. With the proposed methodology, it can be recommended in a case study that the significant effects of partition on thermal comfort are observed where the area with neutral sensation and slightly-cool sensation reduces significantly. The occupants feel uncomfortably cold after installing partition. The carbon dioxide concentrations slightly increase in some areas but the average concentration remains acceptable according to ASHRAE standard. Without the reinforcement of the air-conditioning units, the installation of partition at the desired location is not encouraged regarding to occupant’s thermal comfort and indoor air quality.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

121-126

Citation:

Online since:

June 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] A.P. Jones, Indoor air quality and health, Atmospheric Environment. 33 (1999) 4535-4564.

DOI: 10.1016/s1352-2310(99)00272-1

Google Scholar

[2] G. Heidarinejad, M.H. Fathollahzadeh, H. Pasdarshahri, Effects of return air vent height on energy consumption, thermal comfort conditions and indoor air quality in an under floor air distribution system, Energy and Building. 97 (2015) 155-161.

DOI: 10.1016/j.enbuild.2015.04.004

Google Scholar

[3] M. Bojic, F. Yik, T.Y. LO, Locating air-conditioners and furniture inside residential flats to obtain good thermal comfort, Energy and Building. 34 (2002) 745-751.

DOI: 10.1016/s0378-7788(01)00143-8

Google Scholar

[4] T. Karimipanah, H.B. Awbi, M. Sandberg, C. Blomqvist, Investigation of air quality, comfort parameters and effectiveness for two floor-level air supply systems in classrooms, Building and Environment. 42 (2007) 647-655.

DOI: 10.1016/j.buildenv.2005.10.016

Google Scholar

[5] P. Rohdin, B. Moshfegh, Numerical modeling of industrial indoor environments: A comparison between different turbulence models and supply systems supported by field measurements, Building and Environment. 46 (2011) 2365-2374.

DOI: 10.1016/j.buildenv.2011.05.019

Google Scholar

[6] ANSI, ASHRAE Standard 55, Thermal Environmental Conditions for Human Occupancy, American Society of Heating, Refrigerating, and Air-conditioning Engineers, Atlanta (2010).

Google Scholar

[7] P.O. Fanger, Calculation of thermal comfort, Introduction of a basic comfort equation. ASHRAE transactions. 73 (1967) 1-20.

Google Scholar

[8] ISO Standard 7730, Moderate thermal environments–Determination of the PMV and PPD indices and specification of the conditions for thermal comfort. (1994).

DOI: 10.3403/00814151

Google Scholar

[9] J.M. Daisey, W.J. Angell, M.G. Apte, Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information, Indoor air. 13 (2003) 53-64.

DOI: 10.1034/j.1600-0668.2003.00153.x

Google Scholar

[10] S. Atthajariyakul, T. Leephakpreeda, Real-time determination of optimal indoor-air condition for thermal comfort, air quality and efficient energy usage, Energy and Buildings. 36 (2004) 720-733.

DOI: 10.1016/j.enbuild.2004.01.017

Google Scholar

[11] ASHRAE Standard 62, Ventilation for Acceptable Indoor Air Quality, American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta (2001).

Google Scholar

[12] P.O. Fanger, Thermal environment-Human requirements, Environmentalist. 6 (1986) 275-278.

Google Scholar