Abstract:

A new type of hybrid wood-bamboo shear wall was studied. Ply-bamboo is used as the sheathing panel for conventional two-by-four lightweight woodframe shear walls herein. Two different nails were adopted for the ease constructability and used for constructing the shear walls, as follows: gun-driven T shape nail and 6d common nail. Monotonic and cyclic test results of sheathing-frame connectors and corresponding full scare shear walls were also reported. The results obtained from the research reported in this paper indicated that ply-bamboo panels can be used as sheathings for light-weight timber shear walls.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

529-536

Citation:

Online since:

July 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Z. Li, Y. Xiao, R. Wang, G. Monti, Studies of nail connectors used in wood frame shear walls with ply-bamboo sheathing panels, Journal of Materials in Civil Engineering, DOI: 10. 1061/(ASCE)MT. 1943-5533. 0001167 (2014).

DOI: 10.1061/(asce)mt.1943-5533.0001167

Google Scholar

[2] Y. Xiao, Z. Li, R. Wang, Lateral loading behaviors of lightweight wood-frame shear walls with ply-bamboo sheathing panels, Journal of Structural Engineering, DOI: 10. 1061/(ASCE)ST . 1943-541X. 0001033 (2014).

DOI: 10.1061/(asce)st.1943-541x.0001033

Google Scholar

[3] J.W. van de Lindt, Evolution of wood shear wall testing, modeling, and reliability analysis: Bibliography, Practice Periodical on Structural Design, 9, 1 (2004) 44-53.

DOI: 10.1061/(asce)1084-0680(2004)9:1(44)

Google Scholar

[4] ASTM, Standard test methods for mechanical fasteners in wood, West Conshohocken, PA: ASTM International, (2006).

Google Scholar

[5] H. Krawinkler, F. Parisi, L. Ibarra, A. Ayoub, R. Medina, Development of a testing protocol for wood frame structures, CUREE Publication No. W-02, Richmond, CA, (2000).

Google Scholar

[6] F. Lam, H.G.L. Prion, M. He, Lateral resistance of wood shear walls with large sheathing panels, Journal of Structural Engineering, 123, 12 (1997) 1666-1673.

DOI: 10.1061/(asce)0733-9445(1997)123:12(1666)

Google Scholar

[7] M. He, H. Magnusson, F. Lam, H.G.L. Prion, Cyclic performance of perforated wood shear walls with oversize OSB panels, Journal of Structural Engineering, 125, 1 (1999) 10-18.

DOI: 10.1061/(asce)0733-9445(1999)125:1(10)

Google Scholar