Theoretical and Experimental Study on Mechanical Force of Transformer Coil Short Circuit

Article Preview

Abstract:

As one of the most important components of transmission equipment in electric power field, power transformer bears the important task of energy conversion, power distribution and energy transfer. Because generated a huge force in transformer winding by its interior circuit excitation, it would be taken place easily to distortion, collapse and other damage of its structure, which brings a large safe and reliable problem. The lack of mechanical strength of the coil, which cannot withstand the sudden short-circuit current impact, led to the break of insulating layers, is one of the main causes in transformer failure. In this paper, it is discussed that theoretical and experimental study on mechanical force of transformer coil short circuit. According to the structural mechanics, the calculation of the contacted pressure between the coils is attained by building the contacted model. And the experimental system is been designed, which has a servo control system. Compared the theoretical and the Experimental data, the best accurate computed method for contacted pressure is obtained. It is helpful to improve the resistance ability for short circuit of transformer, and provide guarantee for the safe operation of the transformer.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

283-290

Citation:

Online since:

July 2017

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2017 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Songlin Xu. Discussion on the application of the principle of current ratio in transformer protection. Hefei: HeFei University of Technology, (2008).

Google Scholar

[2] Hongfang Wei, Naiqing Wang, Tongsheng Li. Study on the axial stability of large power transformer windings, power system technology, 23(4)(1999) 8-12.

Google Scholar

[3] Capacity of GB1094. 5-2008 power transformer to withstand short circuit. China Standard Press, (2006).

Google Scholar

[4] Junting Luo. Two factors that affect the capacity of transformer short-circuit fault. Transformer, Vol. 11 No. 5, pp: 8-13, (2008).

Google Scholar

[5] Huaijin Yu. Large Transformer Leakage Magnetic Field and Short Circuit Electrodynamic Force Calculation and analysis. Harbin: Harbin Institute of Technology, (2011).

Google Scholar

[6] Mengyun Wang. 110kV and above transformer faults and defects and statistical analysis. Electricity, 24(1)(2007) 1-5.

Google Scholar

[7] Hong Wang. 110kV Transformer Fault Analysis. Electrical Equipment, 5(12) (2009) 45-47.

Google Scholar

[8] Donglin Wang. Calculation and analysis of short circuit of large transformer windings. Baoding: North China Electric Power University, (2008).

Google Scholar