A Study on Porcelain Insulator Flashover Voltage Evaluation System on Atmospheric Pollution Condition

Article Preview

Abstract:

The industrial development has been aggravating the atmospheric pollution increasingly. The pollution flashover has always been one of the most important problems that bother the development of electric power system in China. The key to prevent the happening of pollution flashover accident is that the electric power operation department can timely and correctly master the condition of external insulation of insulator string in operation to take measures before the happening of pollution flashover accident so as to prevent the happening of pollution flashover accident. The thesis introduces a set of pollution flashover voltage evaluation system for porcelain insulator which can anticipate the pollution flashover voltage of insulator and prevent the happening of the pollution flashover accident through monitoring the weather conditions such as the temperature and humidity, electric parameters such as the leakage current and circuit operating conditions such as the voltage class and type of insulator and considering their influences comprehensively. According to the set of pollution flashover evaluation system, we had a mass of tests in the thesis to fully verify the accuracy and reliability of this system that satisfy the requirement of electric power department.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1008-1009)

Pages:

610-614

Citation:

Online since:

August 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Z. Guan, S. Wang, X. Liang: High Voltage Engineering, Vol. 26-06 (2000), p.37.

Google Scholar

[2] Z. Guan, Y. Liu and Y. Zhou: Insulator and Electric Transmission and Transformation Equipment External Insulation (Tsinghua University Press, Beijing 2004).

Google Scholar

[3] L. Wang, Z. Li and Y . Chen: Electrical Equipment, Vol. 04-06 (2003), p.14.

Google Scholar

[4] H. Huan: Research on Insulator Pollution Flashover Estimation Basing on Leakage Current Characteristic Quantity (Thesis of Ph. D of Chongqing University, Chongqing 2008).

Google Scholar

[5] Y. Mao: Research on Monitoring and Estimation Method of Electric System External Insulation Basing on Leakage Current (Thesis of Ph. D of Tsinghua University, Beijing 2008).

Google Scholar

[6] H. Mei, Y. Mao and X. Bian: High Voltage Engineering, Vol. 36-03 (2010), p.627.

Google Scholar

[7] Y. Mao , Z. Guan and L. Wang: Proceedings of the CSEE, Vol. 27-27 (2007), p.7.

Google Scholar

[8] C. Zhao, Z. Zhou and S. Gao: submitted to Annual Report Conference on Electrical Insulation and Dielectric Phenomena, IEEE Publishing (2012).