Determination of Pb2+ in Wastewater by Lead(II)-dithizone-xylenol Orange Tenary Complex Spectrophotometry
Abstract:
An novel Lead (II)-dithizone-xylenol orange tenary complex spectrophotometry was developed for the determination of Pb2+ in wastewater. For this purpose, the parameters of spectrophotometry such as the detection wavelength, pH value, the dosage of dithizone-xylenol orange and reaction time were studied and optimized through orthogonal tests. The method was linear in the ranges from 2.1×10-3 to 6.0 μg·mL-1 for Pb2+ with R2 ≥ 0.999. The procedure allowed efficient recovery of the investigated Pb2+ ranging between 95 % and 103 % with a relative standard deviation (RSD) ≤ 2.1 for actual wastewater samples spiked with 1.00, 2.00 and 3.00 μg·mL-1 of standard Pb2+, respectively. These results show the method can be applied to the direct determination of Pb2+ in wastewater, avoiding the use of toxic extrant (chloroform) and masking reagent (sodium cyanide) in the traditional methods and time-consuming procedures, moreover, the investigated method is simple, accurate, reliable, and inexpensive, which implies the potential of this technique for Pb2+ monitoring in wastewater samples.