Reliability Evaluation for the Main Electrical Wiring of Pumped-Storage Power Station Based on the GO Methodology

Article Preview

Abstract:

This paper introduced the function of the Pumped-Storage Power Station in power grid and the significance of reliability evaluation. Based on the principle of the GO method, the main electrical wiring’s reliability of the pumped-storage power station is proposed for the first time. According to the original data in references, the GO chart is established and the reliability is calculated and analyzed and evaluation indexes are put forward. The results show that the method is feasible. Finally it expounds the existing problems and shortcomings.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1030-1032)

Pages:

574-578

Citation:

Online since:

September 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Zhang Jian, Zhen Yuan: Pumped storage technology , publishing by hohai university press, Nanjing(2011), pp.1-19.

Google Scholar

[2] Wang Nan, Bai Jianhua, Liu Guiyuan: Foreign pumped storage power station development experience and relevant inspiration, submitted to Journal of China power, (2009).

Google Scholar

[3] Wang Liya: Introduction to pumped storage unit reliability management, submitted to Journal of China power, (2003).

Google Scholar

[4] Zhang Liang, Pan Jufang, Cheng Qin: Tongbai pumped storage unit reliability analysis, submitted to Journal of zhejiang water conservancy and hydropower college(2011).

Google Scholar

[5] Bie Zhaohong, Wang Xifan: Pumped-storage power station main wiring reliability comprehensive evaluation, submitted to Journal of Automation of electric power systems(2006).

Google Scholar

[6] Li Wenyuan: Power system risk assessment model, method and application, translated by Zhou Jiaqi, publishing by science press, Bei Jing(2006), pp.75-81.

Google Scholar

[7] Zhao Ke: substation main electrical wiring reliability evaluation Based on the GO method, Master, taiyuan university of technology(2010).

Google Scholar

[8] Cao Jinglei, Liu Chengzhi, Cheng Yong: main substation main wiring reliability analysis Based on the GO method, submitted to Journal of Electrician electrical(2010).

Google Scholar

[9] Han Fuchun, Zhao Ke, Li Chunye: the main electrical wiring reliability evaluation Based on the GO method, submitted to Journal of Electric technology(2010 ).

Google Scholar

[10] Zhu Jiemin: PuShiHe pumped-storage power station main electrical wiring reliability assessment, Pumped storage power station project construction corpus(mark the tenth anniversary of pumped storage professional committee set up)(2005).

DOI: 10.4028/www.scientific.net/amr.1030-1032.574