Abstract:

Moisture is a major source of damage in historic solid masonry. Rising damp is a well-known phenomenon around the world and occurs when groundwater flows into the base of a construction and is allowed to rise through the pore structure. From practical experience it is known that many factors may play a role regarding permeability problems in masonry. The amount of possible causes of moisture problems in historic masonry underlines the complexity of this phenomenon. Evaporation is an important factor in rising damp. The surface of an affected wall contains moisture that has risen from the ground and this moisture is then subject to evaporation. The factors controlling evaporation include: temperature, humidity, air movement and surface.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

183-186

Citation:

Online since:

October 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] M. Balík et al.: Dehumidification of buildings, 2. vydanie, Praha: Grada, 2008 , 307s. ISBN 978-89-247-2693-9. (in Czech).

Google Scholar

[2] M. Balík, Drying of the masonry, Praha: Grada, 2009, 120s. ISBN 978-80-247-3045-5.

Google Scholar

[3] Construction Yearbook, Bratislava: Jaga Group, 2007, 168s, ISBN 80-8076-030-6. (in Czech).

Google Scholar

[4] J. Řehák, Survey of drainage tunnels in the monastery Milevsko, [online]. Praha, 1993. [s. a. ]. [2014-5-15]. (in Czech) Available on: <http: /old. speleo. cz/soubory/speleo/sp16/milevsko. htm>.

Google Scholar

[5] E. Burgová, R. Matejček, Proposal for remediation of damp masonry church. Giles in Mliesk [online]. Praha: ČVUT, SvF, 2008. [s. a. ]. [2014-5-15]. (in Czech) Available on: <http: /www. asb. sk/stavebnictvo/rekonstrukcia/navrh-sanacie-vlhkeho-muriva-kostola-sv. -jilji-vmilevsku>.

Google Scholar

[6] M. Havel, Procedure for remediation of damp masonry locks on the upper Vimperk, [online]. Bratislava, 2012. [s. a. ]. [2014-5-15]. (in Slovak) Avialable on: < http: /www. asb. sk/stavebnictvo/rekonstrukcia/postup-sanacie-vlhkeho-muriva-horneho-zamku-vo-vimperku>.

Google Scholar

[7] T. Renčko, A. Sedláková, Assessment of underfloor ventilation of historic buildings using. In: Budownictwo o zoptymalizowanym potencjale energetycznym. No. 1Krakow, 2011, pp.98-106. ISSN 2299-8535.

DOI: 10.17512/bozpe

Google Scholar

[8] T. Brestovič, N. Jasminská, M. Kubík, Development of software support for ANSYS CFX. In: 32. stretnutie katedier mechaniky tekutín a termomechaniky Žilina, pp.5-8. - ISBN 978-80-554-0715-9. (in Slovak).