Characteristics of Multi-Storied Brick-and-Concrete Buildings Response to Blasting Vibration of Tunnel Excavation

Article Preview

Abstract:

According to fire station of Tuandao road along to the Yunnan road tunnel of Qingdao Cross-harbor Tunnel Guide Line Project, the blasting vibration test was carried on. This building is three-storied brick-and-concrete building. Then monitoring data of particle vibration velocity was analysised and researched. The results showed that there is magnifying effect of vertical vibration velocity on the roof of the building, but its value is lesser than particle vibration velocity of the first layer. Horizontal tangential vibration velocity was existed on the central of the building. However there was no magnifying effect of horizontal radial vibration velocity. And its value is decreased rapidly from the first layer to the second layer, and then other floors basically keep steady.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 163-167)

Pages:

2608-2612

Citation:

Online since:

December 2010

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Hailiang Wang: Engineering Blasting. (China Railway Publishing House, China 2008).

Google Scholar

[2] Jifu Meng: Blasting monitor knowledge. (Metallurgical Industry Press, China 1992).

Google Scholar

[3] Yong-ji Huo: Blasting. Forum Vol. 20(2003), p.1~6.

Google Scholar

[4] Hua-qi Zhang, Song-xin Zhang: Blasting. Forum Vol. 24(2007), p.98~111.

Google Scholar

[5] Yunpeng Li. Modern Tunneling Technology. Forum Vol. 10(2008), p.59~64.

Google Scholar

[6] Hailiang Xu. Chinese Journal of Underground Space and Engineering. Forum Vol. 8(2007), p.609~612.

Google Scholar