Material Test on Aluminum Alloy Round Pipe for Building Structure

Article Preview

Abstract:

With the unilateral extending test on 4 teams*12 aluminum alloy round pipes, compressing test on 4 teams*4 pipes and repeating extending/compressing test on 4 teams*4 pipes, get the stress-strain relationship of the aluminum alloy round pipe, and get the elastic modulus f0.1 and f0.2. At the same time, get the conclusion that the damaging type is brittleness. The test result is the foundation for follow-up studies on the loading capacity of the aluminum alloys.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 194-196)

Pages:

981-984

Citation:

Online since:

February 2011

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Italy, F.M. Mazzolani, translated by Tan Mei Zhu, Aluminum Alloy Structures, Metallurgy Pressing, 1992(In Chinese).

Google Scholar

[2] Narayanan R. Aluminum structures [M]. London and New York: Elsevier Applied Science, (1987).

Google Scholar

[3] ECCS. European Recommendations For Aluminum Alloy Structures [S]. FIRST edn. (1978).

Google Scholar

[4] National code, GBT228-2002, Extending Test Method of Metal Material under Normal Temperature, China NSO Committee, 2002(In Chinese).