Study on the Performance Efficiency of A2/O Humic Activated Sludge System Operating in Low Temperature

Article Preview

Abstract:

In this article, analysis the A2/O humic activated sludge system phosphorus removal efficiency and CODCr removal efficiency at 5°C, 10°C and 25°C. The results show that A2/O humic activated sludge system phosphorus removal rate when the influent temperature is above 10°C maintained at 86.1% ~ 97.5% performed high phosphorus removal efficiency. But at 5°C the system’s phosphorus removal efficiency decreased to 58.31% couldn’t get the sewage discharge standard. The variation of influent temperature had little influence on the removal efficiency of CODCr even at 5°C performed high removal efficiency.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

187-190

Citation:

Online since:

July 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] YIN Jun: Start-up of A2/O humic activated sludge system phosphorus removal efficiency analysis (Advanced Materials Research VoL. 113-116, 2010).

Google Scholar

[2] YINJun: Study on SBR Filled with Humus Soil for Domestic Sewage Treatment(China Water & Wastewater 2008 VoL. 17).

Google Scholar

[3] WU Chengqiang: Effect of operating Temperature on Characteristics of Activated Sludge(China Water & Wastewater 2003 VoL. 19).

Google Scholar

[4] LI Nan: PERFORMANCE AND REMOVAL APPROACHES OF BIOLOGICAL PHOSPHORUS REMOVAL FROM WASTEWATER IN SBR UNDER LOW TEMPERATURE (D) Harbin Institute of Technology(2010).

Google Scholar