Experimental Study on Seismic Performance of Tall Building Structure of Concrete Filled Steel Tube (CFST) with Transfer Story

Abstract:

Article Preview

The seismic performance test of the model CFST tube structure with transfer story has been finished. The model with 13 floors and with a scale of 1:10 consists of an outer-tube and an inner-tube. The former is a framed tube supported on CFST frames and the latter is an RC tube. A series of seismic performance tests of the model, which is equivalent as two degrees of freedom system, on acceleration earthquake waves in four cases (0.22g, 0.4g, 0.62g and 1.0g) have been fulfilled. The experiment has illustrated that the CFST tube structure is an outstanding structural style with excellent anti-seismic behavior.

Info:

Periodical:

Advanced Materials Research (Volumes 287-290)

Edited by:

Jinglong Bu, Pengcheng Wang, Liqun Ai, Xiaoming Sang, Yungang Li

Pages:

1882-1887

DOI:

10.4028/www.scientific.net/AMR.287-290.1882

Citation:

B. W. Chen et al., "Experimental Study on Seismic Performance of Tall Building Structure of Concrete Filled Steel Tube (CFST) with Transfer Story", Advanced Materials Research, Vols. 287-290, pp. 1882-1887, 2011

Online since:

July 2011

Export:

Price:

$35.00

In order to see related information, you need to Login.

In order to see related information, you need to Login.