Numerical Study on Indoor Air Quality of Commercial Kitchen in China

Article Preview

Abstract:

Indoor air quality of commercial kitchen is investigated and analyzed through velocity, temperature, humidity, and CO2 concentration under different air change rate and supply air temperature. the best air change rate is 30 times per hour and air supply temperature is 301.15K for kitchen, the mean value of the minimum velocity and standard deviation is 0.410m/s and 0.129 respectively, the maximum of the average concentration of CO2 is 659.78ppm, which is less than the acceptance criteria (CO2<1000ppm), and the energy utilization coefficient is maximum of 1.352. Research results show that this air supply mode can optimize indoor air quality.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 374-377)

Pages:

1100-1105

Citation:

Online since:

October 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Risto Kosonen The effect of supply air systems on the efficiency of a ventilated ceiling. Building and Environment Volume 42, Issue 4, April 2007, Pages 1613-1623

DOI: 10.1016/j.buildenv.2005.09.030

Google Scholar

[2] Wyon, D. P. 1996. Individual microclimate control: Required range, probable benefits and current feasibility. In Proceedings of Indoor Air '96, Institute of Public Health,Tokyo.

Google Scholar

[3] Gergen PJ ,Fowler JA,Maurer KR,Davis WW,Overpeck MD(1998).The burden of enviromental tobacco smoke exposure on the repiratory health of children 2 months through 5 years of age in the United States:Third National Health and Nutrition Examination Survery ,1988 to 1994,Pediatrics,101(2):e8.

DOI: 10.1542/peds.101.2.e8

Google Scholar

[4] Nazaroff WW,Singer BC(2004).Inhalation of hazardous air pollutants from particle TEAM study in Riversid PG,California,Journal of Expsure Analysis and Enviromental Epidemiology,6:57-78

Google Scholar

[5] JIANG Da-hua,LI Xian-wei,Li Hui.The Numerical Analysis of Two Ventilation Modes in Public Building Kitchens[J]. Journal of Jiangxi University of Science and Technology,2010,31(5):12-15.

Google Scholar

[6] Dahua Jiang, Angui Li, Faen Shi. Numerical Simulation of IAQ under Up-suction Exhaust Hood in Commercial Kitchen[J].Advanced Materials Research Vols. 250-253 (2011) pp.3228-3231.

DOI: 10.4028/www.scientific.net/amr.250-253.3228

Google Scholar

[7] Nazaroff WW,(2004).indoor particle dynamics. indoor Air,14(Suppl7):175-183

DOI: 10.1111/j.1600-0668.2004.00286.x

Google Scholar

[8] Lai ACK(2004).Modeling of airborne particle exposure and effectiveness of engineering control strategles.Building and Enviroment ,39:599-610

DOI: 10.1016/j.buildenv.2003.12.005

Google Scholar

[9] Long CM,Suh HH,Koutrakis P(2000).Characterization of indoor particle source using continuous mass and size monitor .Journal of the Air&Waste Manage Association ,50:1236-1250

DOI: 10.1080/10473289.2000.10464154

Google Scholar

[10] Lai ACK(2004).Modeling of airbone particle exposure and effectiveness of enginerring control strategies .Building and Environment ,39:599-610

DOI: 10.1016/j.buildenv.2003.12.005

Google Scholar

[11] Merayer C,Wang Z,Kleinerman RA,Wang L,Brenner AV ,Cui H ,Cao J,Lubin JH (2002).Cooking oil fumes and risk of lung cancer in women in rural Gansu,China .Lung Cancer ,35:111-117

DOI: 10.1016/s0169-5002(01)00412-3

Google Scholar

[12] T.P. Ng, K.P. Hui, W.C. Tan, Respiratory symptoms and lung function effects ofdomesticexposureto tobaccosmoke and cooking by gas in non-smoking women in Singapore, Journal of Epidemiology and Community Health 47 (6) (1993) 454–458.

DOI: 10.1136/jech.47.6.454

Google Scholar

[13] Sung-OK B, Kim Y-S, Perry R. Indoor air quality in homes, offices and restaurants in Korean urban areas indoor/outdoor relationships. Atmos Environ 1997;31:529544.

DOI: 10.1016/s1352-2310(96)00215-4

Google Scholar