Analysis on Orthogonal Test of L-Shaped Concrete-Filled Rectangular Composite Steel Tubular Columns
Abstract:
Through orthogonal test, the main influencing factors to the ultimate bearing capacity, ductility and energy consuming ability of L-shaped concrete-filled rectangular composite steel tubular columns are studied. Research results show as follows: the most important factor in deciding the ultimate bearing capacity is the steel tube wall thickness; the most important factor in deciding the ductility factor is the steel tube wall thickness; the most important factor in deciding the equivalent viscous damping coefficient is the strength classes of concrete. At the same time the best level combination of these factors are got.