Development of Passive Energy Dissipation Device with U-Shaped Steel Damper Based on Quasi-Linear Motion Mechanism

Article Preview

Abstract:

This paper presents a new energy dissipation device for earthquake protection of structures. The proposed device, which uses a quasi-linear motion mechanism, achieves dissipation of seismic energy into the structure through yielding of U-shaped steel dampers. Consequently bracing members are subjected to only tensile force. Cyclic loading tests of the portal moment frames with the proposed device are conducted. Results and discussions are presented with emphasis on key features which affect energy dissipation capability. The lateral load and story drift angle relationships show that the proposed device provides stable and reasonably large energy dissipation capability. The effect of pre-tension applied to the bracing members is also examined through the brace axial strain and lateral load relationship.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 446-449)

Pages:

2656-2660

Citation:

Online since:

January 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Y.E. Ibrahim, J. Marshall and F.A. Charney: A visco-plastic device for seismic protection of structures," Journal of Construction Steel Research, 63 (2007), pp.1515-1528.

DOI: 10.1016/j.jcsr.2007.01.007

Google Scholar

[2] R. Sabelli, S. Mahin and C. Chang: Seismic Demands on Steel Braced Frame Buildings with Buckling-Restrained Braces," Engineering Structures, 25 (2003), pp.655-666.

DOI: 10.1016/s0141-0296(02)00175-x

Google Scholar

[3] R.W.K. Chan, F. Albermani and M.S. Williams:Evaluation of Yielding Shear Panel Device for Passive Energy Dissipation, Journal of Construction Steel Research,65(2009),pp.260-268.

DOI: 10.1016/j.jcsr.2008.03.017

Google Scholar

[4] H. Yoshikawa, E. Saeki, A.Watanabe, and K. Suzuki: Experimental Study of U-shaped Steel Damper (Part 2: Test of U-shaped Dampers with Rubber Bearings), Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan B-2, Structure II(1999), pp.667-668. (in Japanese)

Google Scholar

[5] A. Iwasaki, K. Inoue, K. Suita, Y. Koetaka and N. Uno: Study on Dampering Mechanism for H-section Beam-to-Column Connections, Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan C-1, Structure III (2002), pp.639-640. (in Japanese)

Google Scholar