Abstract:

This paper proposed a kind of new control method for resolving the problem of the Direct Torque Control (DTC)'s greater torque pulsation problem at low speed, this method is based on Space Vector Pulse Width Modulation (SVPWM). SVPWM is a kind of excellent Pulse Width Modulation (PWM) scheme. It can not only improve the inverter DC voltage utilization, reduce harmonic losses, restrain torque pulsation, also easily generate high-precision real-time waveform by the high-speed digital signal processor. The simulation results of this system by Matlab/Simulink indicate that the space vector PWM direct torque control can efficiently reduce the pulse of motor torque and flux linkage.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 466-467)

Pages:

819-823

Citation:

Online since:

February 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Xu Yanping, Zhong Yanru: Based on space vector PWM new type of direct torque control system simulation. Journal of System Simulation, Feb (2007), pp.345-347.

Google Scholar

[2] Isao. Takahash: A new quick-response and high-ef ficiency control strategy of an induction motor, IEEE Trans, On Industry Application, May (1986), pp.820-827.

Google Scholar

[3] Chen Boshi: Electric drive control system. 3rd edition, Beijing, China Machine Press (2005).

Google Scholar

[4] K. Rajashekara, A. Kawamura and K. Matsuse: Sensorless Control of AC Motor Drives. New York, IEEE Press (1996).

Google Scholar

[5] Gao Jingde: Analysis of alternative current machine and its system, Beijing, Qinghua University Press (2005).

Google Scholar