Levels and Possible Sources of Formaldehyde in Campus

Article Preview

Abstract:

There are kinds of indoor pollutants in air. Formaldehyde is the most common pollutions in air, especially after a house was decorated. Formaldehyde pollution sources includes adhesives in the man-made board, paint, paint cleaner, pesticides, antiseptic and so on. Campus is the place where population are relatively dense and people stay relatively for a long time. Measuring the pollution levels of formaldehyde in campus can provide basic data to have better understanding of the environmental poblems. In this study, the formaldehyde concentration inside the campus were carefully analyzed and the results showed that the value were all in safe scope, though in the south gate the value was almost near the safety limit at rush our. The formaldehyde in campus mainly came from the manmade woods and car emitting. Well ventilated and green plant were suggested to lower our surroundings of formaldehyde concentration.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 479-481)

Pages:

546-549

Citation:

Online since:

February 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] World Health Organization (WHO), Regional Office of Europe: Development of WHO guidelines for indoor air quality world health organization, 2006.

Google Scholar

[2] Zhao, P.; Lin, C. C., Air Quality at Night Markets in Taiwan. J Air Waste Manage 2010, 60 (3), 369-377.

DOI: 10.3155/1047-3289.60.3.369

Google Scholar

[3] Maruo, Y. Y.; Nakamura, J., Portable formaldehyde monitoring device using porous glass sensor and its applications in indoor air quality studies. Anal Chim Acta 2011, 702 (2), 247-253.

DOI: 10.1016/j.aca.2011.06.050

Google Scholar

[4] Baez, A.; Padilla, H.; Garcia, R.; Torres, M. D.; Rosas, I.; Belmont, R., Carbonyl levels in indoor and outdoor air in Mexico City and Xalapa, Mexico. Sci Total Environ 2003, 302 (1-3), 211-226.

DOI: 10.1016/s0048-9697(02)00344-3

Google Scholar

[5] Khoder, M. I., Formaldehyde and aromatic volatile hydrocarbons in the indoor air of Egyptian office buildings. Indoor Built Environ 2006, 15 (4), 379-387.

DOI: 10.1177/1420326x06067460

Google Scholar

[6] Kuo, N. W.; Chiang, H. C.; Chiang, C. M., Development and application of an integrated indoor air quality audit to an international hotel building in Taiwan. Environ Monit Assess 2008, 147 (1-3), 139-147.

DOI: 10.1007/s10661-007-0105-5

Google Scholar

[7] IARC. Overall evaluation of carcinogenicity to humans, formaldehyde 88 [50-00-0], monographs series.Lyon: 2004, International Agency for Research on Cancer.

Google Scholar

[8] Golden, R., Identifying an indoor air exposure limit for formaldehyde considering both irritation and cancer hazards. Crit Rev Toxicol 2011, 41 (8), 672-721.

DOI: 10.3109/10408444.2011.573467

Google Scholar

[9] Maruo, Y. Y.; Yamada, T.; Nakamura, J.; Izumi, K.; Uchiyama, M., Formaldehyde measurements in residential indoor air using a developed sensor element in the Kanto area of Japan. Indoor Air 2010, 20 (6), 486-493.

DOI: 10.1111/j.1600-0668.2010.00670.x

Google Scholar

[10] Bako-Biro, Z.; Wargocki, P.; Weschler, C. J.; Fanger, P. O., Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices. Indoor Air 2004, 14 (3), 178-187.

DOI: 10.1111/j.1600-0668.2004.00218.x

Google Scholar

[11] World health organization (WHO), Reducing risks, promoting healthy life. The world health report, 2002.

Google Scholar

[12] Fjällström, P.; Andersson, B.; Nilsson, C., Drying of linseed oil paints: the effects of substrate on the emission of aldehydes. Indoor Air 2003, 13 (3), 277-282.

DOI: 10.1034/j.1600-0668.2003.00193.x

Google Scholar

[13] Nakazawa, H.; Ikeda, H.; Yamashita, T.; Hara, I.; Kumai, Y.; Endo, G.; Endo, Y., A case of sick building syndrome in a Japanese office worker. Ind Health 2005, 43 (2), 341-345.

DOI: 10.2486/indhealth.43.341

Google Scholar

[14] Mui, K. W.; Wong, L. T.; Hui, P. S.; Chan, W. Y., Formaldehyde exposure risk in air-conditioned offices of Hong Kong. Build Serv Eng Res T 2009, 30 (4), 279-286.

DOI: 10.1177/0143624409339613

Google Scholar

[15] Ongwandee, M.; Moonrinta, R.; Panyametheekul, S.; Tangbanluekal, C.; Morrison, G., Concentrations and strengths of formaldehyde and acetaldehyde in office buildings in Bangkok, Thailand. Indoor Built Environ 2009, 18 (6), 569-575.

DOI: 10.1177/1420326x09349897

Google Scholar