Study on the Flow Field in Membrane Bioreactor Research by Using PIV

Article Preview

Abstract:

Membrane bioreactor flow field distribution directly affect effective control of the membrane pollution,and affect the membrane flux greatly. The experiments of membrane bioreactor liquid are measured by using PIV that the measurement areas include membrane bioreactor upper, middle and lower. The experimental data obtained velocity field information through the PIV software analysis. The experimental result indicates that middle of the membrane bioreactor flow field is the most unstable. The experimental measurement result provide membrane bioreactor structure the optimized design, effective control of membrane pollution and raise the membrane flux.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 516-517)

Pages:

1078-1081

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] LU Nan; PU Hong-ping; New Wastewater Treatment Technique-Membrane Bioreactor. Journal of Kunming University of Science and Technology, 2004, 2, 100-101.

Google Scholar

[2] GU Guo-wei; HE Yi-liang. Research and Application of Wastewater Treatment -Membrane Bioreactor. Bei Jing. Chemical Industry Press, 1999.

Google Scholar

[3] SUN He-quan; SHEN Yong-ming; WANG Yong-xue; etc. Introduction of algorithms used in PIV technique [J]. Advances in Water Science, 2004, 15(1):105-108

Google Scholar

[4] Ningyu Liu, Qide Zhang, Gim-Leong China,Eng-Hong Onga,et al. Experimental investigation of hydrodynamic behavior in a real membrane bio-reactor unit[J]. Journal of Membrane Science,2010,353,122-134.

DOI: 10.1016/j.memsci.2010.02.042

Google Scholar

[5] RUAN Chi; SUN Chuan-dong; BAI Yong-lin; etc. The characteristics of the t racer particles used in water flow field for PIV system [J]. Journal of Experiments in Fluid Mechanics, 2006, 6:72-77.

Google Scholar

[6] WEI Chun-hai; WANG Cheng-wen; HUANG Xia. Effect of the orifice diameter of perforated pipe on a submerged membrane bioreactor. China Environmental Science, 2007, 27(2):169-173

Google Scholar

[7] ZHANG Chuan-yi; WANG Yong; HUANG Xia; etc .Experimental study on economical aeration intensity in a submerged membrane bioreactor. Membrane Science and Technology, 2004, 24(5):11-15.

Google Scholar

[8] CHEN Yong-Yan,TIAN Rui,LIN Li-Hua;Study on the Flow in Air Gap Membrane Distillation by Using PIV.JOURNAL OF ENGINEERING THERMOPHYSICS,2011,7(7):1137-1140.

Google Scholar