The Application of Regression Analysis in the Characteristics Research of Adjustment to Flue Gas Temperature at Furnace Outlet of CFB Boiler

Article Preview

Abstract:

A type of HG-1025/18.64-L.PM41 circulating fluidized bed boiler (CFB) has been put into production since 2009, a lot of significant experiences have been accumulated by the equipment improvement and operation exploration. To further understand the adjustment characteristics of flue gas temperature at furnace outlet, the operation data of 30 operating conditions have been measured, and also the method of regression analysis is applied to research and analyze the correlative factors composed of boiler load rate, ash content as received basis, volatile content as received basis, net calorific value as received basis, particle diameter of feeding coal, bed pressure, primary air ratio, upper secondary air ratio, lower secondary air ratio and oxygen content at furnace outlet.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 518-523)

Pages:

2247-2253

Citation:

Online since:

May 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Liao Peng, Zhang Hong, Liu Lei, et al. Cause Analysis of Central Barrel Drop-out from Cyclonic Separator of 300MW CFB Boiler and Preventive Measures Thereof[ J]. Thermal Power Generation, 2010, (4): 49-51.(In Chinese)

Google Scholar

[2] Sun Xian-bin, Yu Long, Shi Zheng-hai, et al. Study on Design of the First Home-made CFB Boiler Used for 330MW Unit[ J]. Thermal Power Generation, 2009, (11): 19-22.(In Chinese)

Google Scholar

[3] Li Jun, Liu Han-shen, Wang Zhi-wei. Design of Control System for Homemade 410 t/h CFB Boilers[ J]. Thermal Power Generation, 2005, (10): 35-37.(In Chinese)

Google Scholar

[4] Cen Ke-fa , Ni Ming-jiang, Luo Zhong-yang, et al . Circulating Fluidized Bed Boilers-theoretical Design and Operations[M] . Beijing: China Electric Power Press, 1998.(In Chinese)

Google Scholar

[5] Lu Jun-fu, Zhang Jian-sheng, Yue Guang-xi. Circulating Fluidized Bed Boilers-operations and Maintenance[M] . Beijing: China Water-Power Press, 2003.(In Chinese)

Google Scholar

[6] Chinese Academy of Sciences Institute of Mathematics and Statistics Group. Common Mathematical Statistics Method[M] . Beijing: Science Press, 1979.(In Chinese)

Google Scholar

[7] Liao Peng, Liu Hai-feng, Wang Zhi-wei. Study on Over-temperature Control of 300MW CFB Boiler Cyclone Separator[ J]. Power System Engineering, 2009, (1): 37-38.(In Chinese)

Google Scholar