Research on Bake-Out with Dilution Ventilation for Indoor Air Pollution

Article Preview

Abstract:

Bake-out exhaust method was used to significantly accelerate the release of VOCs from building materials. This paper studies the bake-out technology with dilution ventilation for indoor air pollution by experimental works. The baking effectiveness of formaldehyde, benzene, toluene and xylene ranged from 3 to 7.6, 7.6 to 25, 5.1 to 17 and 6 to 22 for the six cases, respectively. Baking effectiveness would become higher at longer baking time and higher baking temperature for formaldehyde and VOCs released from decorative materials. However, considering the possible deformation of building materials, 40°C and 10 hr would be the best choice for a suitable bake-out.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 518-523)

Pages:

2749-2752

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] P. Wargocki, D.P. Wyon, Y.K. Baik, G. Clausen and P.O. Fanger: Perceived Air Quality, Sick Building Syndrome (SBS) Symptoms and Productivity in an Office with Two Different Pollution Loads, Indoor Air. Vol. 9 (1999), pp.165-179.

DOI: 10.1111/j.1600-0668.1999.t01-1-00003.x

Google Scholar

[2] R. Runeson, K. Wahlstedt, G. Wieslander and D. Norbäck: Personal and psychosocial factors and symptoms compatible with sick building syndrome in the Swedish workforce, Indoor Air. Vol. 16 (2006), pp.445-453.

DOI: 10.1111/j.1600-0668.2006.00438.x

Google Scholar

[3] K. Saarela, T. Tirkkonen, J.L. Ylijoki, J. Jurvelin, M.J. Nieuwenhuijsen and M. Jantunen: Exposure of population and microenvironmental distributions of volatile organic compound concentrations in the EXPOLIS study, Atmospheric Environment. Vol. 37 (2003), pp.5563-5575.

DOI: 10.1016/j.atmosenv.2003.09.031

Google Scholar

[4] B. Stenberg, M.K. Hansson, M. Sandstrom, J. Sundell and S. Wall: A prevalence study of the sick building syndrome (SBS) and facial skin symptoms in office workers, Indoor Air. Vol. 3 (1993), pp.71-81.

DOI: 10.1111/j.1600-0668.1993.t01-2-00002.x

Google Scholar

[5] H. Guo, F. Murray: Characterization of total volatile organic compound emissions from paints, Clean Product and Processes. Vol. 2 (2000), p.28–36.

DOI: 10.1007/s100980050048

Google Scholar

[6] R. Wiglusz, E. Sitko, G. Nikel, I. Jarnuszkiewicz and B. Igielska: The effect of temperature on the emission of formaldehyde and volatile organic compounds from laminate flooring-case study, Building and Environment. Vol. 37 (2002), pp.41-44.

DOI: 10.1016/s0360-1323(00)00091-3

Google Scholar

[7] A. Nozaki, K. Ikura, S. Yoshizawa: Effects of bake out as a source control technique for indoor chemical substances, Journal of Architecture, Planning and Environmental Engineering. Vol. 530 (2000), pp.61-66.

Google Scholar

[8] H. Guo, F. Murray: Characterization of total volatile organic compound emissions from paints, Clean Product and Processes. Vol. 2 (2000), p.28–36.

DOI: 10.1007/s100980050048

Google Scholar

[9] Y. Xu, Y.P. Zhang: An improved mass transfer based model for analyzing VOC emissions from building materials, Atmospheric Environment. Vol. 37 (2003), pp.2497-2505.

DOI: 10.1016/s1352-2310(03)00160-2

Google Scholar

[10] J. Li, J. Liu, Y. Lv, B. Xie and S. Deng: Improve of IAQ by a New Bake-out Method Based on Chamber Tests: In Proceedings of Indoor Air 2005, The 10th International Conference on Indoor Air Quality and Climate, Beijing, China 4-9 September. Vol. 5 (2005), pp.3075-3079.

Google Scholar