The Research on Treating Waste Water Containing Copper by HAP

Article Preview

Abstract:

In this experiment, the copper-containing wastewater was adsorbed by HAP which was prepared by high temperature calcination after high temperature cooking fish scales. By the single factor experiments and orthogonal experiments, the optimal conditions were as follows: the initial concentration of copper ion was 200mg/L,the dosage of HAP was 0.2g,the reaction time was 30min,and pH was 5. The maximum removal efficiency was 98.23%.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 550-553)

Pages:

2146-2150

Citation:

Online since:

July 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Li S,Zhang S,Chen W,et al.Bioceramics,1996,9:225–227

Google Scholar

[2] Yin M Z, Han Y C, Bauer I W,et al.Biomed Mater,2006,1(1):38-41

Google Scholar

[3] Deptula A, Lada W, Olczak T, et a1. Non-crystalline Solids. 1992,147/148:537~54

Google Scholar