Research about Efficiency of Seismic Mitigation for the Dry Friction Plate-Spring Reverted System in High-Rise Building
Abstract:
A theoretical analyzing approach about a novel tuned mass damper system, on high-rise building, was derived according to Lagrange Equation. The solution was programmed with MTALAB software based on the Longe-Kuta method. Computation results show that the displacement, the velocity, and the moment of the highest point were significantly decreased with this system. The system will exhibit the best efficiency with he slip friction factor being 0.01, the spring coefficient 10000KN/m,the damping coefficient 100000 KN/m s and the tuned mass 1.0 times of the mass of per length of the structure.