Kinetic Analysis on Rotating Biological Contactor Treatment of Organic Matter
Abstract:
This paper adopts a 3-stage rotating biological contactor (RBC), studies kinetic analysis on RBC treatment of organic matter .Water temperature 25 °C and hydraulic retention time (HRT) 5h , COD concentration of influent varies from about 400 to 700mg / L, the average COD removal rate is 85% . According to Monod and Michaelis-Menten formula, organic matter removal kinetics equation in the first stage of RBC can be catched. When DO≥2mg/L, organic matter removal kinetic equation: U1=7.02S1/( S1+640.70), DO<2mg/L, organic matter removal kinetic equation: U2=35.97S2/( S2+4848.92) .Where U is substrate removal rate of unit area of disc, S is the organic matter concentration of substrate. Some reference values of the equation are very useful for practical application of RBC.
Info:
Periodical:
Pages:
322-325
Citation:
Online since:
November 2012
Authors:
Keywords:
Price:
Сopyright:
© 2012 Trans Tech Publications Ltd. All Rights Reserved