Analysis of Energy and Environmental Benefits about Ground-Source Heat Pump under Heating Conditions in Wuhan Region

Article Preview

Abstract:

Based on the heating season testing of ground-source heat pump system (GSHP) in Wuhan, the article discussed the energy efficiency ratio of ground-source heat pump system under the heating conditions. By comparison with conventional chillers & coal-fired boiler system, the system energy savings, environmental benefits and incremental payback period are analysized. There comes to the conclusion that the energy saving rate of the heating season is about 19.74% higher than that of the cooling season, reducing 18.35 kg carbon dioxide emissions, 0.15kg of sulfur dioxide and 0.0743 kg of dust per unit construction area each year. Also this article concludes the annual energy saving rate of ground-source heat pump system equals to that of water-source heat pump, with the payback period 22% longer and the cost-effective ratio 32% higher.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 608-609)

Pages:

974-978

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Euiyoung Kima, Jaekeun Leea, Youngman Jeonga, Yujin Hwanga, Sangheon Leeb and Naehyun Parkb: Energy and Buildings. Vol. 50 (2012), P. 1

Google Scholar

[2] D. P. Jenkins, R. Tucker and R. Rawlings: Energy and Buildings. Vol. 41 (2009), P. 587

Google Scholar

[3] C. Montaguda, J.M. Corberána, Á. Monteroa and J.F. Urchueguíab: Energy and Buildings. Vol. 43 (2011), P. 3618

Google Scholar

[4] N. Pardo, Á.Montero, A.Salab, J.Martosc and J.F. Urchueguia: Applied Thermal Engineering. Vol. 31 (2011), P. 391

Google Scholar

[5] Hepbasli and A.Performance: International Journal of Energy Research. Vol. 26 (2002), P. 1121

Google Scholar

[6] Yuyun Li: HV&AC (In Chinese). Vol. 6, 36 (2006), P. 111.

Google Scholar

[7] Yanhua Chen, Zhongyi Yu, Pingfang Hu, Fei Lei, Sun Qiming and Zhangning Jiang: HV&AC (In Chinese). Vol. 6, 39 (2009), P. 12

Google Scholar

[8] Ministry of construction people's republic of China and General Administration of Quality Supervision Inspection and Quarantine of The People's Republic of China: GB50189-2005, Design standard for energy efficiency of public buildings (In Chinese, China Building Industry Press, Beijing 2005).

Google Scholar

[9] Ministry of Housing and Urban-Rural Development of the People's Republic of China: JGJ/T177-2009, Standard for energy efficiency test of public buildings (In Chinese, China Building Industry Press, Beijing 2010).

Google Scholar

[10] China Academy of Building Research Institute: Construction of renewable energy demonstration project evaluation guideline (In Chinese, Beijing 2008).

Google Scholar

[11] Wei Xu , shifeng Sun , Tao He, Yehui Song: Construction Science And Technology (In Chinese). Vol. 16 ( 2009), P. 40

Google Scholar

[12] Jijie Luo and Qiang Zhang: HV&AC (In Chinese). Vol. 7, 39 ( 2009) , P. 132

Google Scholar

[13] Qian Yiming, in: Air conditioning and energy saving of High-rise building (Tongji University Press, Shanghai 1990)

Google Scholar

[14] Shijun You, Qiusheng Li and Ruixin Li: GAS & HEAT (In Chinese). Vol. 2, 24(2004), P. 429

Google Scholar

[15] General Administration of Quality Supervision, Inspection. and Quarantine of The People's Republic of China and National Standardization Management Commission of China: GB/T2589-2008, General principles for calculation of total production energy consumption ( In Chinese, Standards Press of China, Beijing 2008.5).

Google Scholar