Kinetic Analysis of COD Removal from Actual Domestic Wastewater in an Expanded Granular Sludge Bed (EGSB) Reactor

Article Preview

Abstract:

Treatment of actual domestic wastewater at ambient temperature, even low temperature is considered to be difficult by traditional systems. The present study is related to treatment of actual domestic wastewater in an EGSB reactor. The study showed the effectiveness of biological treatment of actual domestic wastewater involving appropriate microorganism and granules in an EGSB reactor. At 26°C, the reactor was operated at 18.7kg COD.m−3.d−1 of average organic loading and 83% high COD removal efficiency, and even at the highest loading rate of 57.12kgCOD.m−3.d−1, the COD removal efficiency still could attain to 68%. Varied influent flow need to supply varied optimal and thus to ensure the optimal removal effect. Low temperature would cause pollutant removal rate decrease. However, enhancing could optimize the contact of sludge and wastewater and thus strengthen the performance effect. Modified Stover–Kincannon model was applied to data obtained from experimental studies in EGSB reactor. Treatment efficiencies of the reactor were investigated at different hydraulic retention times (0.5-1.3h) and different operation temperature (15°C, 26°C). The modified Stover–Kincannon model was best fitted to the EGSB reactor, and the substrate utilization rate( ), saturation constant value( ), and actual pollutant removal rate( ) were found to be , , and for 26°C, , , and for 15°C( before increasing ), and , , and for 15°C(after increasing ). Low temperature could cause decrease and thus cause distinct decreasing of COD removal efficiency. However, increasing could increase and accordingly increase COD removal efficiency.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 610-613)

Pages:

1691-1695

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Kato, T.M., Field, J.A., Versteeg, P., Lettinga, G. Biotechnol. Bioeng. 44(1994), 469-479

Google Scholar

[2] Rebac, S., van Lier, J.B., Janssen, M.G.J., Dekkers, F., Swinkels, K.T.M., Lettinga, G. J. Chem. Tech. Biotechnol. 68(1997), 135-146.

DOI: 10.1002/(sici)1097-4660(199702)68:2<135::aid-jctb583>3.0.co;2-c

Google Scholar

[3] Van Lier, J.B., Rebac, S., Lens, P., van Bijnen, F., Oude Elferink, S.J.W., Stams, J.M., Lettinga, G. Wat. Sci. Tech. 36 (6/7)(1997), 317-324.

DOI: 10.2166/wst.1997.0606

Google Scholar

[4] Rebac, S., Ruskova, J., Gerbens, S., van Lier, J.B., Stams, A.J.M., Lettinga, G. J. Fermen. Bioengin. 80 (5)(1995), 15-22.

DOI: 10.1016/0922-338x(96)80926-3

Google Scholar

[5] Kettunen, R.H., Rintala, J.A. Appl. Microbiol. Biotechnol. 48(1997), 570-576

Google Scholar

[6] Anne-Marie Enright, Sharon McHugh1, Gavin Collins et al. Wat. Res. 39(2005), 4587–4596

Google Scholar

[7] Anne-Marie Enright, Gavin Collins, Vincent O'Flaherty. Wat. Res. 41(2007),1465-1472

Google Scholar

[8] Lin, C.Y., Noike, T., Sato, K., Matsumoto, J. Wat. Sci. Tech. 19(1987), 299-310

Google Scholar

[9] Colm Scully, Gavin Collins, Vincent O'Flaherty. Wat.Res.40(2006),3737-3744.

Google Scholar

[10] Kincannon D. F. and Stover E. L. Design methodology for fixed film reaction-RBCs and biological towers. In Civil Engineering for Practicing and Design Engineers,Vol.2(1982), pp.107-124. Pergamon Press, New York.

Google Scholar

[11] State environmental protection administration of china. Water and wastewater monitoring and analytical methods. Beijing: China Environmental Science Press. (2004)

Google Scholar