Surface Reflectance for Illuminance Level Control in Daylit Historical Museum Gallery under Tropical Sky Conditions

Article Preview

Abstract:

Malaysia has tropical sky conditions, receiving plenty of natural light throughout the year. Natural light fluctuates greatly and it can be rather tricky to provide good distribution of daylight throughout an interior space and this prompts the need for strategic daylight control programme in a historic museum gallery. Surface reflectance is a significant design consideration, particularly with regards to how light is distributed throughout an interior space. Research on how the internal surfaces reflectances are controlled for long-term preservation of museum exhibits is still lacking for tropical skies conditions. The study aims to assess the internal surface reflectance contribution at a west facing daylit historical museum gallery through in-situ measurements and simulation model assessment. The results obtained in these experiments are visually compared with the existing surface reflectance values through simulation modelling. The results show new knowledge on light damage issues. The results also highlight daylighting distributions control and light exposure limits through realistic predictions’ images and reflectance’s alterations. The study confirms that surface reflectances can be a control mechanism for preventive conservation in the historical museum gallery.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 610-613)

Pages:

2854-2858

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wilson, M., "Lighting in museums: Lighting interventions during the European demonstration project 'Energy efficiency and sustainability in retrofitted and new museum buildings' (NNES-1999-20). International Journal of Sustainable Energy, 2006.Vol. 25, No. 3-4: p. pp.153-169, 2006.

DOI: 10.1080/14786450600921546

Google Scholar

[2] Padfield, T., "The role of standards and guidelines: Are they a substitute for understanding the problem or aprotection against the consequences of ignorance?, in 1994, <http://conservationphysics.org/ppubs/dahlem.pdf>, 1994.

Google Scholar

[3] Westerhuis, S., "Preventive Conserving" 2004, <http://www.westerhuis-restauratie>, 2004.

Google Scholar

[4] Thomson, G., The Museum Environment. 2nd ed. 1986, London: Butterworths.

Google Scholar

[5] Joarder, M.A.R., Ahmed, Z.N., Price, A.D.F and Mourshed M.M., A Simulation Assessment of the Height of Light Shelves to Enhance Daylighting Quality in Tropical Office Buildings Under Overcast Sky Conditions in Dhaka, Bangladesh. Eleventh International IBPSA Conference, Glasgow, Scotland, July 27-30, 2009. Building Simulation. 2009.

Google Scholar

[6] LCC, L., Daylighting System Performance Specifications. Retrieved from <http://lightlouver.com/index.php?/daylighting-partners/existing-building-initiative/daylighting-system-performance-specifications/>February 2011.

Google Scholar

[7] Envelope & Room Decisions. . 2011, Retrieved from <http://windows.lbl.gov/daylighting/designguide/section3.pdf>.

Google Scholar

[8] Center, P.E., Daylight Model Construction and Analysis. Pacific Energy Center Factsheet. Retrieved from <http://www.pge.com/pec>.

Google Scholar

[9] N. Ibrahim, A.Z.-A., Daylight Availability in an Office Interior Due to Various Fenestration Options, in 2nd. PALENC Conference and 28th AIVC Confrence on Building Low Energy Cooling and Advanced Ventilation Technologies in the 21st Century. September 2007: Crete Island, Greece.

Google Scholar

[10] Al Tamimi, N.A., S.F. Syed Fadzil and W.M. Wan Harun, The Effects of Orientation, Ventilation, and Varied WWR on the Thermal Performance of Residential Rooms in the Tropics. Journal of Sustainable Development, 2011. Vol. 4, No 2, April 2011.

DOI: 10.5539/jsd.v4n2p142

Google Scholar

[11] J.M. del Melendez: An evaluation of daylight distribution as an initial preventive conservation measure at two Smithsonian Institute Museums, Washington Dc, USA. Journal of Cultural Heritage, 2010.

DOI: 10.1016/j.culher.2010.05.003

Google Scholar

[12] A.N.M Shahriar and M.A. Mohit, Estimating depth of daylight zone and PSALI for side lit office space using the CIE Standard General Sky. Journal of Building and Environment, 2007. No 42, (2007) 2850-2859.

DOI: 10.1016/j.buildenv.2006.10.021

Google Scholar

[13] Fonseca, R.W., A Study on Daylighting Internally Reflected Component; Correlation Between Theoretical and Real Architectural Models in PLEA 2008-25th Conference on Passive and Low Energy Architecture. 22nd to 24th October 2008. Dublin.

Google Scholar