An Integrated Protection of Micro-Grids Based on Bi-Directional Blocking Principle

Article Preview

Abstract:

Reliable and accurate microgrid protection is significant for micro-grid operation.traditional proection methods can not meet the requirements of microgrid.this paper discusses the problems of the existing micro-grid protection methods. Then proposed a new microgrid protection scheme which uses integrated protection as the main protection of microgrid. this protection scheme is based on bi-directional blocking principle,which will send blocking signal if there is no fault .thus protects microgrid. The proposed method is proved to be an effective method for microgrid.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 614-615)

Pages:

1065-1068

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wang Zhiqun,Zhu Shouzhen,Zhou Shuangxi,Controller design for inverter-based distributed genaration.[J]Automation of Electric Power Systems,Vol.28,No.24,Dec.25,2004 ,pp.61-66.

Google Scholar

[2] ZHAO Yue-ling, LI Hua-zhong , SUN Ming. Effect of DG on the distance protection and recloser of transformer substation.[J],Vol.38,No.20,Oct.16,2010,pp.217-224.

Google Scholar

[3] SCHUMACHER E F.Small is beautiful:a study of economics as if people mattered.London.UK:Blond&Briggs.1973.

Google Scholar

[4] LASSETER R H.Microgrid//Proceedings of 2002 IEEE Power Engineering Society Winter Meeting:Vol1,Jan27-31,2002, NewYork, NY, USA. Pmcataway,NJ, USA: IEEE,2002,pp.305-308.

Google Scholar

[5] H.Nikkhajoei R.H. Lasseter.Microgrid Protection.Power Engineering Society General Meeting,2007.IEEE,June 24-28,2007[C].IEEE Conferences,2007.

DOI: 10.1109/pes.2007.385805

Google Scholar

[6] Mahinda Vilathgamuwa D,Loh Poh Chiang,LiYunwei.Protection of Microgrids during utility voltage sags.[J],IEEE Transactions on Industrial Electronics, Vol.53,No.5,Oct.2006,pp.1427-1436.

DOI: 10.1109/tie.2006.882006

Google Scholar

[7] H.AL-NASSERI,M.A.REDFERN.Harmonics content based protection scheme for Micro-grids dominated by solid state converters, 2008, IEEE, 12th International MiddleEast Power System Conference,2008.

DOI: 10.1109/mepcon.2008.4562361

Google Scholar

[8] ZHOU Nian-cheng,JIA Yan-hai,ZHAO Yuan.A new high-speed protection scheme for distribution network. [J], Power System Technology ,Vol.29.No.23,Dec.2005, pp.94-97.

Google Scholar

[9] HE Jing-han,ZHANG Biao. Integrated protection of Multi-Line based on transient current polarity comparison principle.[J],Journal of Beijing Jiaotong University,Vol.31,No.3,Jun.2007.pp.105-108

Google Scholar

[10] BO Zhi-qian, H E Jing-han, DONG Xin-zhou. The integrated protection for power network.[J],RELAY,Vol.33,No.14,Jul.16,2005,pp.6-10.

Google Scholar

[11] Z Q Bo,A T Johns,R K Aggarwal.A new directional relay based on the measurement of fault generatede current transients.Developments in power system protection,march 25-27th.pp.227-230.

DOI: 10.1049/cp:19970069

Google Scholar