Numerical Simulation on the Characteristic of a Solar Chimney

Article Preview

Abstract:

The air flow and heat transfer performance of a solar chimney with the inclination angle of 30deg was investigated by using numerical method. It was found that there is a correlation between solar radiation and ventilation rate and there is a temperature field under the effect of thermal pressure. The research result shows that in the certain scope of research, the ventilation rate is influenced by solar radiation. With the solar radiation increasing, the temperature of chimney decrease along direction from the heat absorption wall to the glass cover-plate surface, and the air flow speed distribute nonuniform along the channel width direction.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 614-615)

Pages:

712-715

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Sun Meng, Liu Jing, Lei Jin et al. Numerical simulation of Enhanced Natural Ventilation with solar energy chimney (in Chinese) [J].Building Science, 2006, 22(6A):26-29.

Google Scholar

[2] Su Xing, Liu Chuanju, Su Jiping. The research on ventilation effect and the application of the solar energy chimney (in Chinese) [J].Energy technology, 2005, 26(6):245-247

Google Scholar

[3] Xu Shuhui, Dong Haiguang, Ma Tianlei. The research of temperature distribution characteristics of solar energy chimney auxiliary room mixed ventilation (in Chinese) [J]. Building Science, 2010, 26(10): 47-52

Google Scholar

[4] N K Bansal, R Mathnr, M S Bhandari. A study of solar chimney assisted wind tower system for natural ventilation in buildings [J].Building and environment, 1994, 29(4): 495-500

DOI: 10.1016/0360-1323(94)90008-6

Google Scholar

[5] B Zamora, A S Kaiser. Numerical study on mixed buoyancy-wind driving induced flow in a solar chimney for building ventilation [J].Renewable Energy, 2010, 35(10)2080-2088

DOI: 10.1016/j.renene.2010.02.009

Google Scholar

[6] B Zamora, A S Kaiser. Optimum wall-to-wall spacing in solar chimney shaped channels in natural convection by numerical investigation [J]. Appl Therm Eng 2009; 29:762 Appl ThermEng 2009; 29:762 —9

DOI: 10.1016/j.applthermaleng.2008.04.010

Google Scholar

[7] Z D Chen, Y Li. A numerical study of solar chimney with wall heat flux, 4th international Conference on Indoor Air Quality, Ventilation and Energy Conservation in Building (IAQVEC2001) OCT 02-05, (2001)

Google Scholar

[8] A Bejan.Convective Heat Transfer [M].New York: John Wiley&Sons, (1995)

Google Scholar

[9] G GAN, S B Riffat.A Nurnerical Study of Solar Chimney for Natural Ventilation of buildings with Heat Recovery [J].Applied Thermal and Engineering, 1998, 18: 1171-1187

DOI: 10.1016/s1359-4311(97)00117-8

Google Scholar