An Experimental Study of Radiant Cooling for Buildings in a Tropical Climate

Article Preview

Abstract:

This paper presents an experimental study of radiant cooling for building air-conditioning in a tropical climate. To prevent condensation of moisture on the cooling panel, the temperature of chilled water supplied to the panel was limited to 25°C. This led to the limitations of heat extraction capacity at the panel and its application to only space with low thermal load and low metabolic rate activity of people in the space. A simple calculation of radiative and convective heat exchange between the interior room surfaces and the room air was applied to determine the rate of heat extraction by the panels. The calculation results can match well with the measurement results. Using a comfort index of predicted mean vote (PMV), the results from experiments show that thermal comfort could be achieved with the application of radiant cooling.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 622-623)

Pages:

1570-1574

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] H.E. Feustel, C. Stetiu, Hydronic radiant cooling-preliminary assessment, Energy and Buildings 22 (1995), p.193–205.

DOI: 10.1016/0378-7788(95)00922-k

Google Scholar

[2] T. Imanari, T. Omori, K. Bogaki, Thermal comfort and energy consumption of the radiant ceiling panel system: comparison with the conventional all-air system, Energy and Buildings 30 (1999), p.167–175.

DOI: 10.1016/s0378-7788(98)00084-x

Google Scholar

[3] X. Sui and X. Zhang, Effects of radiant terminal and air supply terminal devices on energy consumption of cooling load sharing rate in residential building, Energy and Buildings. (2012).

DOI: 10.1016/j.enbuild.2012.02.052

Google Scholar

[4] K. Nagano, T. Mochida, Experiments on thermal environmental design of ceiling radiant cooling for supine human subjects, Building and Environment 39 (2004) 267–275.

DOI: 10.1016/j.buildenv.2003.08.011

Google Scholar

[5] K. Kitagawa, N. Komoda, H. Hayano, S.I. Tanabe, Effect of humidity and small air movement on thermal comfort under a radiant cooling ceiling by subjective experiments, Energy and Buildings 30 (1999) 185–193.

DOI: 10.1016/s0378-7788(98)00086-3

Google Scholar

[6] P. Simmonds, Practical applications of radiant heating and cooling to maintain comfort conditions, ASHRAE Transactions 102 (1996) 659–666.

Google Scholar

[7] R.A. Meierhans, Room air conditioning by means of overnight cooling of the concrete ceiling, ASHRAE Transactions 102 (1) (1996) 693–697.

Google Scholar

[8] ASHRAE, ASHRAE Handbook–Fundamentals, Ch. 8, American Society of Heating, Refrigerating and Air-Conditioning Engineers Inc., Atlanta (2001).

Google Scholar