Approach to Calibrated Simulation Tool for Improved Building Performance

Article Preview

Abstract:

Simulation tools represent continuous, stochastic processes in buildings by discrete time-step, deterministic model estimations. All models make assumptions when representing real buildings. Detailed models more closely represent the operation of the real building and allow Energy Conservation Measures (ECM) to be investigated at finer resolution, using fewer assumptions. This paper presents a systematic, evidence-based approach to calibrated simulation. This approach yields a calibrated model that is based solely on referenced sources of information about the building. The proposed methodology builds on some of the best techniques from the reviewed literature and combines these with an evidence-based approach that uses version control software to track the calibration process.Although the process produces a single, deterministic model for an inherently stochastic process (building operation), such an approach can produce meaningful conclusions where sub-utilities hourly measured data and significant resources for further investigation and measurement are available.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

22-25

Citation:

Online since:

May 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Ascione F, De Rossi F, Vanoli GP. Energy retrofit of historical buildings: theoretical and experimental investigations for the modelling of reliable performance scenarios. Energy and Buildings. 2011 Aug; 43(8):1925–36.

DOI: 10.1016/j.enbuild.2011.03.040

Google Scholar

[2] Olsen, E.L. and Chen, Q. "Energy consumption and comfort analysis for different low-energy cooling systems in a mild climate," Energy and Buildings, 2003, 35(6), 560-571.

DOI: 10.1016/s0378-7788(02)00164-0

Google Scholar

[3] Crawley, D.B, Hand, J.W, L and Lawrie, L.K. Improving the weather information available to simulation programs, in: Proceedings of Building Simulation_99, 2, Kyoto, Japan September, 1999, 13–15, p.529–536.

Google Scholar

[4] Raftery P, Keane M, O'Donnell J. Calibrating whole building energy models: An evidence-based methodology. Energy and Buildings. 2011 Sep; 43(9):2356–64.

DOI: 10.1016/j.enbuild.2011.05.020

Google Scholar

[5] Reddy, T, Maor,IandPanjapornpon,C. Calibrating detailed building energy simulationprograms with measured data—Part 2: application to three case study office buildings, HVAC&R Research. 2007, 13; 243–265.

DOI: 10.1080/10789669.2007.10390953

Google Scholar

[6] Carroll, W.L and Hitchcock, R.J. Tuning simulated building description to matchactual utility data: methods and implementation, ASHRAE Transactions 1993, 99. 928–934.

Google Scholar

[7] ASHRAE Guideline 14-2002: Measurement of Energy and DemandSavings.

Google Scholar

[8] Meyers S, Kromer S. Measurement and verification strategies for energy savings certificates: meeting the challenges of an uncertain world. Energy Efficiency. 2008 Nov 1; 1(4):313–21

DOI: 10.1007/s12053-008-9019-5

Google Scholar

[9] US Department Of Energy, M&V Guidelines: Measurement and Verification for Federal Energy Projects Version 3.0. http://mnv.lbl.gov/keyMnVDocs/femp(2008).

Google Scholar

[10] Agami Reddy T. Literature review on calibration of building energy simulation programs: Uses, problems, procedure, uncertainty, and tools. ASHRAE Transactions. 2006. Page 226–40.

Google Scholar

[11] Yoon, J and Lee E.J, D.E. Claridge, Calibration procedure for energy performancesimulation of a commercial building, Journal of Solar Energy Engineering.2003.125. Page 251–257.

DOI: 10.1115/1.1564076

Google Scholar

[12] Pedrini, A, Westphal,F.Sand Lamberts, R. A methodology for building energymodelling and calibration in warm climates, Building and Environment 2002. 37. Page 903–912.

DOI: 10.1016/s0360-1323(02)00051-3

Google Scholar

[13] Kaplan,M, McFerran, Jansen,andPratt J.R. Reconciliation of a DOE2.1C Modelwith monitored end-use data for a small office building, ASHRAE Transactions. 1990. Page 981–992.

Google Scholar

[14] Pan,Y, Huang,Z and Wu, G. Calibrated building energy simulation and its applicationin a high-rise commercial building in Shanghai, Energy and Buildings. 2007. 39; Page 651–657.

DOI: 10.1016/j.enbuild.2006.09.013

Google Scholar

[15] Iqbal, I and Al-Homoud, M.S. Parametric analysis of alternative energy conservationmeasures in an office building in hot and humid climate, Building and Environment 2007.42; Page 2166–2177.

DOI: 10.1016/j.buildenv.2006.04.011

Google Scholar

[16] Eskin N and Turkmen H, (2008). Analysis of annual heating and cooling energy requirementsfor office buildings in different climates in Turkey, Energy and Buildings 40 763–773.

DOI: 10.1016/j.enbuild.2007.05.008

Google Scholar

[17] Aynur, T.N, Hwang,Yand Radermacher,R.Simulation of a VAV air conditioning system in an existing building for the cooling mode, Energy and Building. 2009. 41: Page 922–929.

DOI: 10.1016/j.enbuild.2009.03.015

Google Scholar

[18] Rahman, M. Rasul, M and Khan,M. Energy conservation measures in an institutionalbuilding in sub-tropical climate in Australia, Applied Energy. 2010. 87; Page 2994–3004.

DOI: 10.1016/j.apenergy.2010.04.005

Google Scholar