On-Site Monitoring of Floor Failure Depth with High Confined Water and Mining Risk Assessment
Abstract:
About under-group coal seams mining with the threat of high-pressure ordovician water, conventional mining technology by draining depressurization usually causes environmental issues such as soil erosion and ground subsidence etc.,By using grouting reinforcement technology, this paper changes floor direct charge layer into relatively separatedwater layer in the coal seam and achieves the goals of sealing the water inrush channel, moreover, on the basis of coal floor failure depth analysis and monitoring, the paper evaluates risk of water-inrush from seam floor when face length increases, On this basis, puts forward a reasonable working face length and mining technology, and has abtained good economic and social benefits in practice.