Study on the Seismic Performance of Cavity Walls Constraint Masonry Construction

Article Preview

Abstract:

Cavity walls structure is unsuitable in cold area for its faultiness of poor heat-insulating property. But the cavity walls constraint masonry construction is suitable in cold area for its high heat-insulating property. Studies are carried as setting up the restoring force model of the cavity walls confined masonry structure and analyzing the dynamic time-history of cavity walls constraint masonry structure under 7 degrees small earthquake, middle earthquake or large earthquake through EL centro wave, TALF wave, Ninghe wave and Qian'an wave, which indicates that cavity walls constraint masonry construction can satisfy seismic demand of 7 degree quake. Finally, the formula for calculating the interlayer displacement of cavity walls confined masonry structure near collapse is put forward and the counting result is compared with that of dynamic time-history analyzing, which shows that the accuracy of this formula is high enough to be used for analyzing the seismic performance of cavity walls constraint masonry structure. Foundation projects: Special Basic Scientific Research for Central Public Institute (2008B002, 2010A04), Open Fund of Key Laboratory of State Education Ministroy on Urben and Engineering Safe and Disaster Diminish & Key Laboratory of Beijing on Engineering Seismic and Treatment (EESR2010-07), and High Level Talent Support Project of Heilongjiang University (HDTD2010-13).

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 724-725)

Pages:

1702-1708

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] ZHAI Ximei, TANG Daixin. Earthquake response analysis of concrete cavity walls structure, J. Journal of Harbin Institute of Technology, 2003,(35):1523-1526.

Google Scholar

[2] FAN Jinzhong. Effective method of improving insulation performance of concrete small block walls, J. walls innovation and building energy saving, 2006:52-55.

Google Scholar

[3] JIN Weiliang, XU Quanbiao, PAN Jinlong. Lateral resistance behavior experimental study of different construction measures of concrete small hollow block masonry, J. Journal of Building Structure, 2001,(22):64-72.

Google Scholar

[4] LI Liqun, LIU Weiqing. Seismic performance research of concrete hollow small block masonry with constructional column, J. Engineering Seismic, 2001,(4):16-20.

Google Scholar

[5] LI Liqun,LIU Weiqing. Seismic performance experimental study of confined concrete small hollow block masonry [J].Journal of Architectural Engineering of Nanjing Institute,2001:19-26.

Google Scholar

[6] XIONG Lihong. Performance -based seismic study of multilayer concrete block structure [D].Harbin:Institute of Engineering Mechanics, China Earthquake Administration.(2004)

Google Scholar

[7] QU Chengzhong, XIE Lili. Study on target displacement determining method on limit state of block masonry structure performance based, J. Earthquake engineering and Engineering Vibration, 2003, (23):18-25.

Google Scholar