Research on the Control Method of High Power APF for Oil Drilling Rig

Article Preview

Abstract:

The wide use of oil drilling rig brings nominated economic profits for oil drilling industry. However, it will bring about great quantities of harmonic current to the grid, lowering the power quality and reliability of the power grid. Meanwhile, harmonic currents will have a deteriorated influence to surrounding electrical equipment and grid. This paper studies the distribution characteristics of the harmonic current in the oil industry and puts forward a control strategy aiming for improving stability and reliability of the power supply system. This paper also proposes an algorithm for detecting harmonic current based on time domain transformation and control strategy based on two cascade (voltage and current) control loop. Experiment and simulation results validate the proposed control strategy.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 734-737)

Pages:

1450-1459

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] L.S. Xiong, F. Zhuo. "A Novel DC Voltage Balancing Method for Cascaded STATCOM". IEEE Applied Power Electronics Conference and Exposition, 2013.

DOI: 10.1109/apec.2013.6520321

Google Scholar

[2] Adrian Timbus, Remus Teodorescu and Frede Blaabjerg. "Synchronization Methods Evaluation". IEEE Power Electronics Specialists Conference, 2005.

DOI: 10.1109/pesc.2005.1581980

Google Scholar

[3] L.S. Xiong, F. Zhuo, M.H. Zhu. "Study on the compound cascaded STATCOM and compensating for 3-phase unbalance loads". IEEE Applied Power Electronics Conference and Exposition, 2013.

DOI: 10.1109/apec.2013.6520759

Google Scholar

[4] Akagi H, Kanazawa, Y. Nabae A. Generalized theory of the instantaneous reactive power in three-phase circuits. In Proc. IEEJ Int. Power Electronics Conf.,(1983)

Google Scholar

[5] J.Nastran. Active power filter for nonlinear AC loads. IEEE Trans. Power Electronics, Vol.9, no.1, 1994 pp.92-96.

DOI: 10.1109/63.285498

Google Scholar

[6] L.S. Xiong, F. Zhuo, Y.X. Zhu. A novel control method for DC voltage of cascaded STATCOM[C]. International Power Electronics and Motion Control Conference, 2012.

DOI: 10.1109/ipemc.2012.6259298

Google Scholar

[7] H.Y. Li. Research on Active Power Filter Applied in Independent Small Rating Power System [D]. Xi'an: Xi'an Jiaotong University, 2005.

Google Scholar

[8] F. Z. Peng, H. Akagi, and A. Nabae. "A new approach to harmonic compensation in power systems-A combined system of shunt passive and series active filters". IEEE Trans. Ind. App., vol.26, pp.983-990, 1990.

DOI: 10.1109/28.62380

Google Scholar

[9] Se-Kyo Chung. "A phase tracking system for three phase utility interface inverters". IEEE Transactions on Power Electronics.2000, Vol. 15, no. 3: 431-438.

DOI: 10.1109/63.844502

Google Scholar

[10] L.S. Xiong, L.Y. Ma, F. Zhuo, L. Sun. "Seamless self-healing control strategy for cascaded multilevel STATCOM". IEEE International Symposium on Industrial Electronics, 2012.

DOI: 10.1109/isie.2012.6237400

Google Scholar

[11] Amirnaser Yazdani, Reza Iravani. Voltage-Sourced Converters in Power Systems Modeling, Control, and Applications. A JOHN WILEY & SONS, LNC. PUBLICATION 2010:245-257.

DOI: 10.1002/9780470551578

Google Scholar

[12] H. Fujita and H. Akagi. "A practical approach to harmonic compensation in power systems-series connection of passive and active filters". IEEE Trans. Ind. App., vol.27, pp.1020-1025, 1991.

DOI: 10.1109/28.108451

Google Scholar