Experimental Study in Determining the Stress Intensity Factor by Using the Grid Method

Article Preview

Abstract:

Grid method was used to measure the stress intensity factor KI of a mode I fracture specimen. The fracture specimen used in this study was a compact tension (CT) specimen made of 6061-T6 aluminum. A grid of dots was bonded along a radial line on the surface of the CT specimen. A 2D computer vision was used to acquire the images around the crack tip before and after the deformation of the CT specimen. Then the method of single dot was used to measure the magnitude and direction of the in-plane principle strains at the dot centers. Experimental results indicate that the measured strains can be used to accurately determine KI.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

612-617

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Williams, M.L., On the Stress Distribution at the Base of a Stationary Crack, Journal of Applied Mechanics, 24, 109-114 (1959).

Google Scholar

[2] Williams, M.L., Stress Singularities Resulting From Various Boundary Conditions in Angular Corners of Plates in Extension, Journal of Applied Mechanics, 74 (1952).

DOI: 10.1115/1.4010553

Google Scholar

[3] Dally, J. W. and Sanford, R.J., Strain-Gage Methods for Measuring the Opening-Mode Stress-Intensity Factor, KI, Experimental Mechanics, December, 381-388 (1987).

DOI: 10.1007/bf02330311

Google Scholar

[4] Kuang, H. J. and Chen, L. S., A Single Strain Gage Method for KI Measurement, Engineering Fracture Mechanics, 51(5), July, 1995, pp.871-878.

DOI: 10.1016/0013-7944(94)00298-v

Google Scholar

[5] Luo, P. F. and Huang, F. C., Application of stereo Vision to the Study of Mixed-mode Crack-tip Deformations, Optics and Lasers in Engineering, 33(5), 349-368, (2000).

DOI: 10.1016/s0143-8166(00)00052-x

Google Scholar

[6] ASTM-Standard E399-90, Standard Test Methods for Plane-Strain Fracture Toughness of Metallic Materials, 1997 Annual Book of ASTM Standard , 03. 01, ASTM (1997).

DOI: 10.1520/stp23697s

Google Scholar

[7] Luo, P. F. and Wu, J., An Easy Calibration Technique for Stereo VisionUsing a Circle Grid, Optical Engineering, 47(3), 033607, (2008).

DOI: 10.1117/1.2897237

Google Scholar

[8] Bookstein, F. L., Fitting Conic Sections to Scattered Data, Computer Grapics and Image Processing, 9, 56-71 (1979).

DOI: 10.1016/0146-664x(79)90082-0

Google Scholar